1. Home /
  2. FSC NSN Catalog /
  3. Hazard-Detecting Instruments and Apparatus /
  4. 06-201

NSN 06-201

Multi-Dosimeter Calibrator

A narrow strip of webbing cut to a definite length, having one or both ends processed. It is usually designed for, and may have, one or more attachments or fasteners, such as buckle; loop, strap fastener; strap end clip; ring, dee; hook; and the like. Excludes:strap, berth, mattress retaining; strap, chin; safety straps; and webbing, textile. Do not use if a more specific item name applies.

multi-dosimeter checker consists of a plastic cylinder with six holes that surround an 8 ci cs-137 exempt source. radioactive source: 8 ci cs-137 (exempt) cylinder materials: gray pvc dimensions: 2.62 diameter x 1.50 high weight: .35 lbs special features, calibrator multidose allows simultaneous testing of 6 dosimeters part name assigned by controlling agency.

NSN 6665-01-460-3115 Datasheet

(NSN) National Stock Number
6665-01-460-3115
(FSC) Federal Supply Classification
6665 - Hazard-Detecting Instruments and Apparatus
(NIIN) National Item Identification Number
01-460-3115
Requires Demilitarization
Yes
(INC) Item Name Code
53475
Date
Mon, Nov 2, 1998
Schedule B Code
9027908950
Part Name Assigned By Controlling Agency
calibrator multidose allows simultaneous testing of 6 dosimeters
Special Features
multi-dosimeter checker consists of a plastic cylinder with six holes that surround an 8 ci cs-137 exempt source. radioactive source: 8 ci cs-137 (exempt) cylinder materials: gray pvc dimensions: 2.62 diameter x 1.50 high weight: .35 lbs

Identification

Demilitarization Code
B - Usml items - mutilation to the point of scrap required worldwide. (note 7).
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0053475

Cross Reference

CAGE Codes

1AU07
Fluke Biomedical, Llc Dba Nuclear Associates, Global Calibration Lab, Inovision
Non-manufacturers
89875
Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia
U.s./canadian manufacturers
067T7
Arrow-Tech, Inc
U.s./canadian manufacturers

Freight Information

Air Commodity
MZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
F - 150.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
06350
Water Commodity
72E - Engineer and material handling equipment, test/tool sets and equipment
National Motor Freight Classification Item Number
014500

Schedule B & Trade

Schedule B
9027-90-8950
Description
parts and accessories of instruments & apparatus for physical or chemical analysis, nesoi
End Use
21160 - Measuring, testing, control instruments
Unit of Quantity
KG
USDA
Yes
(SITC) Standard International Trade Classification
87449
(NAICS) North American Industrial Classification System
334516

Questions & Answers

  1. What is the FSCG of the NSN 6665-01-460-3115?

    The FSCG of the NSN 6665-01-460-3115 is 6665

  2. Does the NSN 6665-01-460-3115 have a Schedule B code assigned?

    Yes, the Schedule B code is 9027908950

  3. Does NSN 6665-01-460-3115 require demilitarization?

    Usml items - mutilation to the point of scrap required worldwide. (note 7).

  4. Does NSN 6665-01-460-3115 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6665-01-460-3115 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 6665-01-460-3115 was assigned to the Federal Catalog?

    It was assigned 27 years ago, on Mon, Nov 2, 1998

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.