1. Home /
  2. FSC NSN Catalog /
  3. Electronic Microcircuits /
  4. 118945-003

NSN 118945-003

Hybrid Microcircuit

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, and the like, shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. For items with step by step variation, see rheostat and resistor, step by step. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. Excludes:resistor (1), variable, wire wound, nonprecision; resistor (1), variable, nonwire wound precision; and resistor (1), variable, wire wound, precision.

1 power supply design function and quantity, 0.780 inches maximum body width, 0.980 inches maximum body length, hermetically sealed features provided, 0.190 inches maximum body height.

NSN 5962-01-347-1697 Datasheet

(NSN) National Stock Number
5962-01-347-1697
(FSC) Federal Supply Classification
5962 - Electronic Microcircuits
(NIIN) National Item Identification Number
01-347-1697
Requires Demilitarization
Yes
(INC) Item Name Code
41014
Date
Thu, Oct 17, 1991
Schedule B Code
8542900000
Body Height
0.190 inches maximum
Body Length
0.980 inches maximum
Body Width
0.780 inches maximum
Design Function And Quantity
1 power supply
Features Provided
hermetically sealed
Hybrid Technology Type
monolithic
Inclosure Configuration
pin grid array
Inclosure Material
ceramic
Input Circuit Pattern
11 input
Operating Temp Range
-55.0 to 105.0 celsius
Terminal Surface Treatment
solder
Terminal Type And Quantity
28 pin
Voltage Rating And Type Per Characteristic
100.0 volts maximum input

Identification

Demilitarization Code
D - Usml or ccl military items - demil required. Destroy item and components to prevent restoration or repair to a usable condition. (note 5).
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Pseudo Item Name Code
0041014

Cross Reference

CAGE Codes

91417
L3harris Technologies, Inc.
U.s./canadian manufacturers
16170
Teledyne Technologies Incorporated Dba Teledyne Microelectronic Technologies Div Teledyne Microelectronics
Non-manufacturers
13499
Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Less than Carload Rating
P - 77.5
National Motor Freight Class Rating
W - Rating variable
Special Handling
Z - Other or no special handling required (sh)
Type of Cargo
3 - Electrostatic sensitive device (esd)
Uniform Freight Classification Item Number
34580
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
061700

Schedule B & Trade

Schedule B
8542-90-0000
Description
electronic integrated circuits and microassembly parts
End Use
21320 - Semiconductors
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77689
(NAICS) North American Industrial Classification System
334413

Questions & Answers

  1. What is the FSCG of the NSN 5962-01-347-1697?

    The FSCG of the NSN 5962-01-347-1697 is 5962

  2. Does the NSN 5962-01-347-1697 have a Schedule B code assigned?

    Yes, the Schedule B code is 8542900000

  3. Does NSN 5962-01-347-1697 require demilitarization?

    Usml or ccl military items - demil required. Destroy item and components to prevent restoration or repair to a usable condition. (note 5).

  4. Does NSN 5962-01-347-1697 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5962-01-347-1697 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 5962-01-347-1697 was assigned to the Federal Catalog?

    It was assigned 34 years ago, on Thu, Oct 17, 1991

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 10 hours ago
View History