1. Home /
  2. FSC NSN Catalog /
  3. Electrical and Electronic Properties Measuring and Testing Instruments /
  4. 152-2001

NSN 152-2001

Ammeter

A device of various shapes to be permanently attached to the structure of an aircraft. It is designed to permanently mount and/or support an integral member, or group of members of the airframe in a proper position and bear the stress imposed by the components being supported. It may have mounting provisions, such as slots, holes, and/or attachments to facilitate installation. Excludes:items which are primarily designed for dampening shock and/or vibration. Excludes:bracket, angle; bracket, double angle; bracket, shelf; bracket, mounting; bracket (1), structural component, aircraft; and radius block.

2 threaded stud circuit attachment method and quantity, white single indicator single range background color, nonelectronic circuit construction type, dc circuit current for which designed, unable to decode accuracy in percent.

NSN 6625-01-112-9979 Datasheet

(NSN) National Stock Number
6625-01-112-9979
(NIIN) National Item Identification Number
01-112-9979
Requires Demilitarization
Yes
(INC) Item Name Code
16450
Date
Thu, May 14, 1981
Schedule B Code
9030908030
Accuracy In Percent
unable to decode
Background Color
white single indicator single range
Circuit Attachment Method And Quantity
2 threaded stud
Circuit Construction Type
nonelectronic
Circuit Current For Which Designed
dc
Dial Scale Marking Color
unable to decode
Dielectric Withstanding Voltage In Volts
5000.0
Features Provided
zero adjuster
Fsc Application Data
test set,electronic equipment
Indicator Type
dial w/pointer
Installation Design
panel
Material
steel
Measurement Range
unable to decode
Meter Body Diameter Behind Mounting Flange
2.210 inches nominal
Meter Depth Behind Mounting Flange
1.556 inches nominal
Mounting Arrangement Style
three hole/stud bolt circle
Mounting Bolt Circle Diameter
2.440 inches nominal
Mounting Facility Type And Quantity
3 threaded stud(s)
Movement Suspension Method
jewel pivot base
Movement Type
moving coil, permanent magnet
Mounting Stud Diameter
0.112 inches nominal
Mounting Stud Length
0.500 inches nominal
Nuclear Hardness Critical Feature
nonhardened
Overall Diameter
2.695 inches nominal
Overall Length
2.031 inches nominal
Panel For Which Designed
magnetic
Pointer Color
unable to decode
Scale Division Quantity
unable to decode
Scale Graduation Type
unable to decode
Scale Selection Method
terminal
Sensitivity Rating
1000.0 ohms per volt
Style Designator
round flush mtg

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0016450

Cross Reference

CAGE Codes

60741
Triplett (bluffton) Corporation Dba Lfe Instruments
U.s./canadian manufacturers
33005
Jewell Instruments Llc
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
H - 110.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
00000
Water Commodity
657 - Instruments, electric meter
National Motor Freight Classification Item Number
136750

Schedule B & Trade

Schedule B
9030-90-8030
Description
parts and accessories of articles of schedule b subheading 9030.39
End Use
21160 - Measuring, testing, control instruments
Unit of Quantity
KG
USDA
Yes
(SITC) Standard International Trade Classification
87479
(NAICS) North American Industrial Classification System
334515

Questions & Answers

  1. What is the FSCG of the NSN 6625-01-112-9979?

    The FSCG of the NSN 6625-01-112-9979 is 6625

  2. Does the NSN 6625-01-112-9979 have a Schedule B code assigned?

    Yes, the Schedule B code is 9030908030

  3. Does NSN 6625-01-112-9979 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6625-01-112-9979 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6625-01-112-9979 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 6625-01-112-9979 was assigned to the Federal Catalog?

    It was assigned 45 years ago, on Thu, May 14, 1981

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.