Scanner,ultrasound,ophthalmic,di

A switch that is externally actuated by a device such as a push rod or button, which requires pushing for each actuation. The action may be momentary, with mechanical return. It consists of a body,switch and a push button. The item may include provisions for mounting indicating lamps or light emitting diodes in the actuator. Includes items consisting of individually separable switches that are physically interlocked, that have a common actuator, or are electrically connected. Excludes: light-switch; light-switch assembly; switch,beam selecting,headlight; switch,foot; switch,interlock; switch,pressure; switch,push-pull; switch,sensitive and switch assembly. For devices which start, stop, reverse, select and/or regulate the speed of a motor, see starter,motor and controller,motor.

120.0 and 240.0 voltage in volts, capable of utilizing a range of transducer frequencies for optimized imaging; measurements of various ophthalmic structures; multi-purpose system intended for use in ophthalmic applications; capture images of the interior of the eye; make accurate measurements of the structures; sonomed vupad b-scan/a-scan system; vupad unit; 2.0kv standard a-probe; 10mhz; 12 mhz b-probe; multi-probe cable; usb foot pedal; 50/60hz 120-240vac auto-switching medical grade power supply; user manual; 25 protective caps for the a-probe; 25 b-probes; 4 protective port covers; carrying case. special features, ophthalmic ultrasound system part name assigned by controlling agency, 50.0 and 60.0 frequency in hertz.

NSN 6540-01-697-2943 Datasheet

(NSN) National Stock Number
6540-01-697-2943
(NIIN) National Item Identification Number
01-697-2943
Requires Demilitarization
Yes
(INC) Item Name Code
46614
Date
Mon, Sep 13, 2021
Schedule B Code
9018500000
Frequency In Hertz
50.0 and 60.0
Part Name Assigned By Controlling Agency
ophthalmic ultrasound system
Special Features
capable of utilizing a range of transducer frequencies for optimized imaging; measurements of various ophthalmic structures; multi-purpose system intended for use in ophthalmic applications; capture images of the interior of the eye; make accurate measurements of the structures; sonomed vupad b-scan/a-scan system; vupad unit; 2.0kv standard a-probe; 10mhz; 12 mhz b-probe; multi-probe cable; usb foot pedal; 50/60hz 120-240vac auto-switching medical grade power supply; user manual; 25 protective caps for the a-probe; 25 b-probes; 4 protective port covers; carrying case.
Voltage In Volts
120.0 and 240.0

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Pseudo Item Name Code
0046614

Cross Reference

CAGE Codes

89875
Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia
U.s./canadian manufacturers
64616
Defense Medical Standardization Board
U.s./canadian manufacturers
63663
Sonomed, Inc. Dba Sonomed Escalon
U.s./canadian manufacturers

Freight Information

Air Commodity
MZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
00000
Water Commodity
651 - Instruments, medical and surgical
National Motor Freight Classification Item Number
056590

Schedule B & Trade

Schedule B
9018-50-0000
Description
other ophthalmic instruments and appliances and parts and accessories
End Use
21610 - Medicinal equipment
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87225
(NAICS) North American Industrial Classification System
339115

Questions & Answers

  1. What is the FSCG of the NSN 6540-01-697-2943?

    The FSCG of the NSN 6540-01-697-2943 is 6540

  2. Does the NSN 6540-01-697-2943 have a Schedule B code assigned?

    Yes, the Schedule B code is 9018500000

  3. Does NSN 6540-01-697-2943 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6540-01-697-2943 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6540-01-697-2943 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 6540-01-697-2943 was assigned to the Federal Catalog?

    It was assigned 5 years ago, on Mon, Sep 13, 2021