1. Home /
  2. FSC NSN Catalog /
  3. Switches /
  4. 161390-DH2

NSN 161390-DH2

Rotary Switch

breaks before makes each section front contact switching action, 1.0 amperes resistive load ac at sea level contact load current rating, unable to decode contact switching action, 110.0 ac at sea levelunable to decode contact voltage rating in volts, 2.0 amperes resistive load dc at sea level contact load current rating.

NSN 5930-00-666-0165 Datasheet

(NSN) National Stock Number
5930-00-666-0165
(FSC) Federal Supply Classification
5930 - Switches
(NIIN) National Item Identification Number
00-666-0165
Requires Demilitarization
Yes
(INC) Item Name Code
02134
Date
Tue, Jan 1, 1963
Schedule B Code
8536509020
Contact Load Current Rating
1.0 amperes resistive load ac at sea level
Contact Load Current Rating
2.0 amperes resistive load dc at sea level
Contact Switching Action
breaks before makes each section front
Contact Switching Action
unable to decode
Contact Voltage Rating In Volts
110.0 ac at sea levelunable to decode
Contact Voltage Rating In Volts
28.0 dc at sea level
Contact Voltage Rating In Volts
unable to decode
First Flat Length
0.312 inches nominal single actuator
First Flat Length
unable to decode
Flat Height
unable to decode
Flat Height
0.219 inches nominal single actuator
Individual Section Quantity
2
Mounting Method
threaded bushing single mounting facility
Mounting Method
unable to decode
Nominal Thread Size
0.375 inches single mounting facility
Nominal Thread Size
unable to decode
Nonturn Device Radius
0.531 inches nominal at 10:30 oclock
Nonturn Device Radius
unable to decode
Nonturn Device Type
tab at 10:30 oclock
Nonturn Device Type
unable to decode
Overall Diameter
2.188 inches maximum
Overall Length
2.750 inches nominal
Pole Quantity
1 each section rear
Pole Quantity
unable to decode
Precious Material And Location
clips and rotors silver
Precious Material
silver
Rotor Through Connection Quantity
1 each section
Rotor Through Connection Quantity
unable to decode
Shaft Diameter
0.250 inches nominal single actuator
Shaft Diameter
unable to decode
Shaft Flat/Slot Angular Location
225.0 degrees from nonturn device single actuator
Shaft Flat/Slot Angular Location
unable to decode
Shaft Length
unable to decode
Shaft Type
round, flatted single actuator
Shaft Type
unable to decode
Shaft Length
0.375 inches nominal single actuator
Style Designator
circular wafer, bushing mount
Switch Actuator Indexing Position Quantity
9 single actuator
Switch Actuator Indexing Position Quantity
unable to decode
Switch Actuator Positioning Increment
30.0 degrees single actuator
Switch Actuator Positioning Increment
unable to decode
Switch Actuator Stop Device Type
fixed stop single actuator
Switch Contact Basic Design
nonpile-up symmetrical
Terminal Type
clip
Thread Class
2a single mounting facility
Thread Length
0.375 inches nominal single mounting facility
Thread Length
unable to decode
Thread Series Designator
unef single mounting facility
Throw Quantity
9 each section front
Throw Quantity
unable to decode

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
S - Item contains silver.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0002134

Cross Reference

CAGE Codes

76854
Electro Switch Corp. Dba Oak Grisgsby Div Electroswitch
U.s./canadian manufacturers
06KW9
Lucent Technologies Inc Dba Federal Marketing Group
U.s./canadian manufacturers
3B4M0
Lucent Technologies Inc Corporate Headquarters
Non-manufacturers
64959
American Telephone and Telegraph Co
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-50-9020
Description
switches, rotary, rated at not over 5 a, for a voltage not exceeding 1,000 v
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77255
(NAICS) North American Industrial Classification System
335931

Questions & Answers

  1. What is the FSCG of the NSN 5930-00-666-0165?

    The FSCG of the NSN 5930-00-666-0165 is 5930

  2. Does the NSN 5930-00-666-0165 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536509020

  3. Does NSN 5930-00-666-0165 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5930-00-666-0165 contain precious materials?

    Item contains silver.

  5. Does NSN 5930-00-666-0165 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5930-00-666-0165 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 1 day ago
View History