1. Home /
  2. FSC NSN Catalog /
  3. Capacitors /
  4. 175D0007

NSN 175D0007

Electrolytic Fixed Capacitor

w/o mtg facilities, axial terminals body style, 0.686 inches nominal body length, 0.289 inches nominal body diameter, solid anode type, tantalum capacitive electrode material.

NSN 5910-00-902-4409 Datasheet

(NSN) National Stock Number
5910-00-902-4409
(FSC) Federal Supply Classification
5910 - Capacitors
(NIIN) National Item Identification Number
00-902-4409
Requires Demilitarization
Yes
(INC) Item Name Code
00008
Date
Fri, Jan 1, 1960
Schedule B Code
8532290040
Anode Type
solid
Body Diameter
0.289 inches nominal
Body Length
0.686 inches nominal
Body Style
w/o mtg facilities, axial terminals
Capacitive Electrode Material
tantalum
Capacitance Value Per Section
47.000 microfarads single section
Case Insulation Material
plastic
Dc Leakage At Reference Temp
7.000 microamperes
Dc Leakage At Maximum Operating Temp
208.0 milliamperes
Dissipation Factor At Reference Temp In Percent
6.0000
Electrical Polarization
polarized
Nonderated Operating Temp
-55.0 celsius minimum and 85.0 celsius maximum
Nonderated Continuous Voltage Rating And Type Per Section
20.0 dc single section
Reliability Indicator
not established
Schematic Diagram Designator
electrode(s) grounded to case, w/gnd terminal
Terminal Diameter
0.025 inches nominal
Terminal Length
1.500 inches minimum
Terminal Surface Treatment
solder
Terminal Type And Quantity
2 uninsulated wire lead
Tolerance Range Per Section
-20.00 to 20.00 percent single section

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0000008

Cross Reference

CAGE Codes

56289
Sprague Electric Co World Hqs
U.s./canadian manufacturers
06481
Northrop Grumman Systems Corporation Div the Navigation, Targeting and Survivability Division
U.s./canadian manufacturers
05397
Union Carbide Corp Materials Systems Div
U.s./canadian manufacturers
06124
Mallory Timers Co Div of Emhart Industries Inc
U.s./canadian manufacturers

Freight Information

Schedule B & Trade

Schedule B
8532-29-0040
Description
fixed capacitors, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77867
(NAICS) North American Industrial Classification System
334416

Questions & Answers

  1. What is the FSCG of the NSN 5910-00-902-4409?

    The FSCG of the NSN 5910-00-902-4409 is 5910

  2. Does the NSN 5910-00-902-4409 have a Schedule B code assigned?

    Yes, the Schedule B code is 8532290040

  3. Does NSN 5910-00-902-4409 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5910-00-902-4409 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5910-00-902-4409 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5910-00-902-4409 was assigned to the Federal Catalog?

    It was assigned 66 years ago, on Fri, Jan 1, 1960

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.