1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. 2002258

NSN 2002258

Circuit Breaker

overcurrent all locations circuit protection type, rectangular dimensional envelope body style, at each pole actuator position designation, one, two, and three linked external actuator linkage arrangement, trip-reset actuator function.

NSN 5925-01-378-8409 Datasheet

(NSN) National Stock Number
5925-01-378-8409
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-378-8409
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Sun, Aug 22, 1993
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at each pole
Body Style
rectangular dimensional envelope
Circuit Protection Type
overcurrent all locations
External Actuator Linkage Arrangement
one, two, and three linked
Fragility Factor
moderately rugged
Inclosure Protection Type For Which Designed
general purpose
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Material
plastic case
Overall Height
3.000 inches nominal
Overall Length
4.000 inches nominal
Overall Width
3.000 inches nominal
Pole Quantity
3
Reset Method
manual
Special Handling Feature
magnetic
Storage Type
general purpose warehouse
Terminal Type And Quantity
6 tab, solder lug
Trip Release Characteristic
instantaneous all locations
Trip Release Method
magnetic all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Unpackaged Unit Weight
2.000 pounds nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

97578
Timken Gears & Services Inc. Dba Philadelphia Gear Div Western Regional Service Center
U.s./canadian manufacturers
50380
Reliance Electric
U.s./canadian manufacturers
71956
Reliance Electric Company Dba Reliance & Dodge Brands
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-378-8409?

    The FSCG of the NSN 5925-01-378-8409 is 5925

  2. Does the NSN 5925-01-378-8409 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-378-8409 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-378-8409 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-378-8409 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-378-8409 was assigned to the Federal Catalog?

    It was assigned 33 years ago, on Sun, Aug 22, 1993

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.