1. Home /
  2. FSC NSN Catalog /
  3. Switches /
  4. 222-32NB4-2221453

NSN 222-32NB4-2221453

Pressure Switch

increase contact action stimulus, 5.00 differential point nominal pounds per square inch gage contact stimulus rating, unable to decode contact load current rating, +15.00 to 50.00 actuation point pounds per square inch gage contact adjustment range, actuation point adjustable contact adjustability.

NSN 5930-00-800-6665 Datasheet

(NSN) National Stock Number
5930-00-800-6665
(FSC) Federal Supply Classification
5930 - Switches
(NIIN) National Item Identification Number
00-800-6665
Requires Demilitarization
Yes
(INC) Item Name Code
00206
Date
Mon, Jan 1, 1962
Schedule B Code
8536509065
Contact Action Stimulus
increase
Contact Adjustability
actuation point adjustable
Contact Adjustment Range
+15.00 to 50.00 actuation point pounds per square inch gage
Contact Load Current Rating
unable to decode
Contact Stimulus Rating
5.00 differential point nominal pounds per square inch gage
Contact Voltage Rating In Volts
unable to decode
Mounting Method
bracket(s)
Nominal Thread Size
unable to decode
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
Overall Height
2.875 inches nominal
Overall Length
6.969 inches nominal
Overall Width
5.000 inches nominal
Pressure Switch Type
gage
Terminal Type
screw
Test Data Document
"81349-mils16032 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Quantity Per Inch
unable to decode
Thread Series Designator
unable to decode

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000206

Cross Reference

CAGE Codes

19278
Detroit Switch Inc Dba Detroit Switch Inc
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-50-9065
Description
switches, for a voltage not exceeding 1000 volts, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77255
(NAICS) North American Industrial Classification System
335931

Questions & Answers

  1. What is the FSCG of the NSN 5930-00-800-6665?

    The FSCG of the NSN 5930-00-800-6665 is 5930

  2. Does the NSN 5930-00-800-6665 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536509065

  3. Does NSN 5930-00-800-6665 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5930-00-800-6665 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5930-00-800-6665 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5930-00-800-6665 was assigned to the Federal Catalog?

    It was assigned 64 years ago, on Mon, Jan 1, 1962

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.