NSN: 5925-00-004-6994
Part Number(s):
Quantity:
Company:
Name & Email:
Phone:
Order Terms | Privacy Policy    

Cross Reference These part numbers have the same form, fit, and function of 2415839-3

Item Number Cage
MP1500-058-1 76374
2415839-3 10001

Characteristic Codes 2415839-3 spec. code meanings

Code Translation
CPRW Denotes the action imparted by actuator operation.
CPRX An indication of the designated position of the actuator.
ADAQ A measurement of the longest dimension of the body, in distinction from width.
AAQL The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
ADAT A measurement taken at right angles to the length of the body, in distinction from thickness.
ABXD A measurement of the longest dimension of a bushing, in distinction from width.
ADTV The element, compound, or mixture of which the case is fabricated, excluding any surface treatment.
AEBP The center to center distance between terminals parallel to the length of the item.
CPRH Indicates the type of electrical condition that will cause the device to trip.
FREQ The cycles per second /hertz/ of the alternating current.
CPLM The maximum current load that each pole is rated to carry continuously.
CPRG Indicates the type and value of the maximum short circuit current that the item will successfully interrupt, per pole, at the specified rated voltage, expressed in amperes.
AXHR Indicates the type and number of facilities by which the item is mounted.
CQJX A designation that is used for the purpose of general identification of the thread.
CPRF Indicates the type and value of operating voltage for which each pole is designed to operate, expressed in volts.
CPSM The basic internal electrical configuration of the trip mechanism.
CPRR Indicates the type of mechanism provided for tripping main contacts.
CPRT Indicates the type and number of actuators provided for manual control.
CPRQ The means provided to reposition the mechanism so that the device is ready to function.
AKPX The number of poles included in the item.
TTQY Indicates the type and number of terminals for providing electrical connection.
CMLP The number of threads on the item per linear inch measured on a line parallel to the thread axis.
THSD A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
CQWN The length of time, expressed in seconds, that an overload may exist before the device will trip at a specified continuous current.
CRCF The temperature of the medium surrounding the trip release at which it can be operated continuously.
CPRL Denotes the type of trip release action.
CPRJ The means by which the trip mechanism is released.
CPRN The continuous current rating per pole at which the device must trip in a specified time, expressed in percent.
CPRP The ultimate time per pole in which the device must trip, expressed in seconds.

2415839-3 Circuit Breaker

Mfr. Cage 10001

Specification

Thread Size: 1/2"

CPRW Actuator Function
Trip-reset
CPRX Actuator Position Designation
At pole one
ADAQ Body Length
1.137 inches
AAQL Body Style
Single pole type
ADAT Body Width
0.750 inches
ABXD Bushing Length
0.250 inches maximum
ADTV Case Material
Plastic
AEBP Center To Center Distance Between Terminals Parallel To Length
0.650 inches
CPRH Circuit Protection Type
Overcurrent single location
FREQ Frequency In Hertz
400.0 single location
CPLM Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location and 1.0 amperes dc single location
CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 60000.0 dc single location
AXHR Mounting Facility Type And Quantity
1 threaded bushing
AJWX Mounting Surface To Terminal End Distance
1.812 inches
CQJX Nominal Thread Size
0.469 inches
CPRF Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location
CPSM Internal Trip Release Configuration
Series trip single location
CPRR Main Contact Tripping Mechanism Type
Trip free
CPRT Manual Actuator Type And Quantity
1 push-pull
CPRQ Reset Method
Manual
AKPX Pole Quantity
1
TTQY Terminal Type And Quantity
2 screw
CMLP Thready Qty Per Inch (tpi)
32
THSD Thread Series Designator
Unc
CQWN Trip Delay Time In Seconds Per Rated Continuous Current
0.400 minimum at 200 pct single location and 2.000 maximum at 200 pct single location
CRCF Trip Release Ambient Temp Rating
200.0 deg fahrenheit maximum single location
CPRL Trip Release Characteristic
Time delay single location
CPRJ Trip Release Method
Thermal single location
CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
CPRP Ultimate Trip Time Per Pole In Seconds
5.000 single location

Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
National Stock Number (NSN) 5925-00-004-6994