Home » FSC Catalog » Circuit Breakers » 2XAM1516HKMG3-30-208-2-60

Price and Stock Check

We will send you instructions on purchasing this NSN*
NSN: 5925-00-004-4024
Part Number(s):
Quantity:
Company:
Name & Email:
Phone:
Order Terms | Privacy Policy    

Cross Reference

These part numbers have the same form, fit, and function of 2xam1516hkmg3-30-208-2-60
Item Number Cage
2XAM1516HKMG3-30-208-2-60 74193

Characteristic Codes

2XAM1516HKMG3-30-208-2-60 spec. code meanings
Code Translation
AAQL The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
ADAQ A measurement of the longest dimension of the body, in distinction from width.
ADAT A measurement taken at right angles to the length of the body, in distinction from thickness.
ADTV The element, compound, or mixture of which the case is fabricated, excluding any surface treatment.
AEBP The center to center distance between terminals parallel to the length of the item.
AEBQ The center to center distance between terminals parallel to the width of the item.
AEBY The distance between centerlines of mounting facilities parallel to the length of the item.
AEGJ A designation that describes the basic electrical configuration of a switch.
AEHA The distance between centerlines of mounting facilities parallel to the width of the item.
AKPX The number of poles included in the item.
APNQ The means of quenching an arc.
AXHR Indicates the type and number of facilities by which the item is mounted.
BBRG Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
CMLP The number of threads on the item per linear inch measured on a line parallel to the thread axis.
CPLM The maximum current load that each pole is rated to carry continuously.
CPRF Indicates the type and value of operating voltage for which each pole is designed to operate, expressed in volts.
CPRG Indicates the type and value of the maximum short circuit current that the item will successfully interrupt, per pole, at the specified rated voltage, expressed in amperes.
CPRH Indicates the type of electrical condition that will cause the device to trip.
CPRJ The means by which the trip mechanism is released.
CPRL Denotes the type of trip release action.
CPRN The continuous current rating per pole at which the device must trip in a specified time, expressed in percent.
CPRQ The means provided to reposition the mechanism so that the device is ready to function.
CPRR Indicates the type of mechanism provided for tripping main contacts.
CPRT Indicates the type and number of actuators provided for manual control.
CPRW Denotes the action imparted by actuator operation.
CPRX An indication of the designated position of the actuator.
CPRY Indicates the arrangement of the externally connected actuators.
CPRZ The function for which the auxiliary switch is designed and the number provided.
CPSM The basic internal electrical configuration of the trip mechanism.
CQJX A designation that is used for the purpose of general identification of the thread.
CQSM Indicates the location of the switch in relation to its designated position.
CQWN The length of time, expressed in seconds, that an overload may exist before the device will trip at a specified continuous current.
CQXF Indicates the type of protection for which the inclosure is designed.
CRTK Indicates the type of terminal for providing electrical connection to the switch.
CSSX The amount of current, expressed in amperes, and the type for which the switch is rated.
CSWP The voltage, expressed in volts, and current type for which the switch is rated.
FREQ The cycles per second /hertz/ of the alternating current.
PKWT The measured weight of an item unencumbered by packaging or packing material.
THSD A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
TTQY Indicates the type and number of terminals for providing electrical connection.

2XAM1516HKMG3-30-208-2-60

Description: Circuit Breaker
Mfr. Cage 74193

Specification

Thread Size: 9/64"

AAQL Body Style
Multipole-multiple actuator type
ADAQ Body Length
3.719 inches
ADAT Body Width
2.031 inches
ADTV Case Material
Plastic
AEBP Center To Center Distance Between Terminals Parallel To Length
3.063 inches
AEBQ Center To Center Distance Between Terminals Parallel To Width
1.031 inches
AEBY Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches
AEGJ Switch Contact Arrangement
Single pole, double throw
AEHA Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.031 inches
AJEC Boss Height
0.156 inches
AJWX Mounting Surface To Terminal End Distance
3.429 inches
AKPX Pole Quantity
2
APNQ Arc Quenching Method
Magnetic blowout
AXHR Mounting Facility Type And Quantity
4 threaded hole
BBRG Storage Type
General purpose warehouse
CMLP Thready Qty Per Inch (tpi)
32
CPLM Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
CPRF Operating Voltage Type And Rating Per Pole In Volts
208.0 ac all locations
CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
CPRH Circuit Protection Type
Overcurrent all locations
CPRJ Trip Release Method
Magnetic-hydraulic all locations
CPRL Trip Release Characteristic
Time delay all locations
CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
CPRQ Reset Method
Manual
CPRR Main Contact Tripping Mechanism Type
Trip free
CPRT Manual Actuator Type And Quantity
2 toggle
CPRW Actuator Function
Trip-reset
CPRX Actuator Position Designation
At each pole
CPRY External Actuator Linkage Arrangement
One and two linked
CPRZ Auxiliary Switch Function And Quantity
1 alarm
CPSM Internal Trip Release Configuration
Series trip all locations
CQJX Nominal Thread Size
0.138 inches
CQSM Switch Location And Position Designation
Internal at pole one
CQWN Trip Delay Time In Seconds Per Rated Continuous Current
5.000 minimum at 200 pct all locations and 18.000 maximum at 200 pct all locations
CQXF Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant
CRTK Switch Terminal Type
Tab, solder lug
CSSX Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
CSWP Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
FREQ Frequency In Hertz
60.0 all locations
PKWT Unpackaged Unit Weight
1.200 pounds
THSD Thread Series Designator
Unc
TTQY Terminal Type And Quantity
4 threaded stud

Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
National Stock Number (NSN) 5925-00-004-4024

Last Modified: 02/14/2017