NSN 4946-2

Electrical Frequency Meter

A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an invertor,vibrator; vibrator,interrupter; vibrator,self-rectifying; invertor,power,static with a transformer and rectifies employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contacts of a vibrator,self-rectifying or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a filter,direct current power and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and enerators and dynamotors.

2.250 inches maximum center to center distance between mounting facilities parallel to length, 2 threaded stud circuit attachment method and quantity, white single indicator single range background color, unable to decode accuracy in percent, 2.250 inches maximum center to center distance between mounting facilities parallel to width.

NSN 6625-01-062-5824 Datasheet

(NSN) National Stock Number
6625-01-062-5824
(NIIN) National Item Identification Number
01-062-5824
Requires Demilitarization
Yes
(INC) Item Name Code
16454
Date
Wed, Jul 19, 1978
Schedule B Code
9030908030
Accuracy In Percent
unable to decode
Background Color
white single indicator single range
Center To Center Distance Between Mounting Facilities Parallel To Length
2.250 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Width
2.250 inches maximum
Circuit Attachment Method And Quantity
2 threaded stud
Circuit Current For Which Designed
ac
Dial Scale Marking Color
unable to decode
Dielectric Withstanding Voltage In Volts
3000.0
Environmental Protection
airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Features Provided
magnetic shield
Frequency Rating
50.0 hertz nominal
Frequency Response Range
+47.500 to 52.500 hertz
Fsc Application Data
test set,elect. equip.
Furnished Items And Quantity
nut 8; lockwasher 6; seal 1
Indicator Type
vibrating reed
Installation Design
panel
Material
plastic
Measurement Range
unable to decode
Meter Body Diameter Behind Mounting Flange
2.800 inches maximum
Meter Depth Behind Mounting Flange
2.312 inches maximum
Mounting Arrangement Style
four hole/stud rectangular/square
Mounting Facility Type And Quantity
4 threaded stud(s)
Movement Type
vibrating reed
Mounting Stud Diameter
0.132 inches nominal
Mounting Stud Length
0.500 inches nominal
Nuclear Hardness Critical Feature
nonhardened
Overall Height
3.125 inches maximum
Overall Length
3.342 inches maximum
Overall Width
3.000 inches maximum
Power Source
external
Register Quantity
2
Resonant Reed Quantity
11
Scale Selection Method
terminal
Special Features
ruggedized
Special Markings
on back,sealed do not open
Special Test Features
complies with mil-m-10304
Style Designator
rectangular flush mtg
Surface Treatment
paint

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0016454

Cross Reference

CAGE Codes

24655
Genrad Inc
U.s./canadian manufacturers
62015
Iet Labs Inc
U.s./canadian manufacturers
07239
Avo Intl
U.s./canadian manufacturers
18876
Us Army Aviation and Missile Command
Government departments or units, including military organizations
0BZM1
Mkc Electronics Inc Dba Mk Electronics Div Mkc Electronics Inc, Dba Mk Electronics
Non-manufacturers

Freight Information

Air Commodity
AZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
J - 100.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34540
Water Commodity
657 - Instruments, electric meter
National Motor Freight Classification Item Number
061620

Schedule B & Trade

Schedule B
9030-90-8030
Description
parts and accessories of articles of schedule b subheading 9030.39
End Use
21160 - Measuring, testing, control instruments
Unit of Quantity
KG
USDA
Yes
(SITC) Standard International Trade Classification
87479
(NAICS) North American Industrial Classification System
334515

Questions & Answers

  1. What is the FSCG of the NSN 6625-01-062-5824?

    The FSCG of the NSN 6625-01-062-5824 is 6625

  2. Does the NSN 6625-01-062-5824 have a Schedule B code assigned?

    Yes, the Schedule B code is 9030908030

  3. Does NSN 6625-01-062-5824 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6625-01-062-5824 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 6625-01-062-5824 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 6625-01-062-5824 was assigned to the Federal Catalog?

    It was assigned 48 years ago, on Wed, Jul 19, 1978

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.