Circuit Breaker

A rigid metal item of various shapes designed to support the front engine and provide the facilities for attachment of the insulator assembly.

at each pole actuator position designation, 2.500 inches nominal body length, trip-reset actuator function, 2.250 inches nominal body width, multipole-multiple actuator type body style.

NSN 5925-00-480-4635 Datasheet

(NSN) National Stock Number
5925-00-480-4635
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
00-480-4635
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Mon, Aug 31, 1970
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at each pole
Body Length
2.500 inches nominal
Body Style
multipole-multiple actuator type
Body Width
2.250 inches nominal
Boss Height
0.140 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Circuit Protection Type
overcurrent all locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
External Actuator Linkage Arrangement
one, two, and three linked
Frequency In Hertz
60.0 all locations
Internal Trip Release Configuration
series trip all locations
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Mounting Facility Type And Quantity
6 threaded hole(s)
Mounting Surface To Terminal End Distance
2.471 inches nominal
Nominal Thread Size
0.138 inches
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Pole Quantity
3
Reset Method
manual
Terminal Type And Quantity
6 threaded stud
Thread Quantity Per Inch
32
Thread Series Designator
unified national coarse (unc)
Trip Release Characteristic
time delay all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Delay Time In Seconds Per Rated Continuous Current
1.800 minimum at 125 pct and 7.000 maximum at 125 pct and 0.900 minimum at 150 pct and 3.000 maximum at 150 pct and 0.300 minimum at 200 pct and 1.000 maximum at 200 pct and 0.110 minimum at 300 pct and 0.300 maximum at 300 pct and 0.044 minimum at 400 pct and 0.150 maximum at 400 pct all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Ultimate Trip Time Per Pole In Seconds
7.000 maximum all locations

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

14304
L3harris Technologies, Inc. Dba Harris Corp Div Harris Defense Communications
U.s./canadian manufacturers
74193
Eaton Corp Heinemann Products Commercial Controls Div
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-00-480-4635?

    The FSCG of the NSN 5925-00-480-4635 is 5925

  2. Does the NSN 5925-00-480-4635 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-00-480-4635 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-00-480-4635 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-00-480-4635 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-00-480-4635 was assigned to the Federal Catalog?

    It was assigned 56 years ago, on Mon, Aug 31, 1970

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.