1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. 6510-002-5

NSN 6510-002-5

Circuit Breaker

A definite continuous length of cable,special purpose,electrical, having one or more ends processed or terminated in fittings which provide for connectionn to other items. For items which the rated working is 300 volts or more, see: cable assembly,power,electrical. Excludes items having branches or forks. Excludes: lead,test and cable and conduit assembly,electrical.

1.530 inches nominal center to center distance between terminals parallel to length, single pole type body style, overcurrent single location circuit protection type, 1.200 inches maximum body width, 2.940 inches nominal distance between centerlines of mounting facilities parallel to body length.

NSN 5925-01-424-2425 Datasheet

(NSN) National Stock Number
5925-01-424-2425
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-424-2425
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Wed, Jan 24, 1996
Schedule B Code
8536200040
Body Style
single pole type
Body Width
1.200 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
Circuit Protection Type
overcurrent single location
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.940 inches nominal
Frequency In Hertz
400.0 single location
Internal Trip Release Configuration
series trip single location
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3600.0 ac single location
Mounting Facility Type And Quantity
2 unthreaded hole(s)
Mounting Surface To Terminal End Distance
4.260 inches maximum
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc and 115.0 ac single location
Overall Length
3.250 inches maximum
Pole Quantity
1
Reset Method
automatic
Specification/Standard Data
81349-mil-c-83383 government specification and 81349--83383/02 government specification
Terminal Type And Quantity
2 threaded stud
Test Data Document
"81349-mil-c-83383 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.). and 81349--83383/02 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Trip Delay Time In Seconds Per Rated Continuous Current
7.000 minimum at 200 pct and 40.000 maximum at 200 pct and 1.200 minimum at 400 pct and 6.400 maximum at 400 pct and 0.300 minimum at 1000 pct and 1.200 maximum at 1000 pct single location
Trip Release Ambient Temp Rating
-54.0 celsius minimum and 71.0 celsius maximum single location
Trip Release Characteristic
time delay single location
Trip Release Method
thermal single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
200.0 single location
Unthreaded Mounting Hole Diameter
0.172 inches nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

76374
Safran Electrical & Power Usa, Llc Dba Labinal Power Sysyems Use Cage Code 81640 for Cataloging
U.s./canadian manufacturers
81349
Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
Military standards and standards organizations (ex:stanags,milspecs,defstans)

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-424-2425?

    The FSCG of the NSN 5925-01-424-2425 is 5925

  2. Does the NSN 5925-01-424-2425 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-424-2425 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-424-2425 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-424-2425 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-424-2425 was assigned to the Federal Catalog?

    It was assigned 30 years ago, on Wed, Jan 24, 1996

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.