1. Home /
  2. FSC NSN Catalog /
  3. Related Equipment, Waveguides and Antennas /
  4. 723398-4

NSN 723398-4

Electrical Dummy Load

self-cooled cooling method, 3.200 inches minimum and 3.240 inches maximum overall height, horizontal operating position, 3.630 inches nominal body diameter, +0.000 to 3.000 gigahertz frequency range rating.

NSN 5985-00-080-1382 Datasheet

(NSN) National Stock Number
5985-00-080-1382
(FSC) Federal Supply Classification
5985 - Related Equipment, Waveguides and Antennas
(NIIN) National Item Identification Number
00-080-1382
Requires Demilitarization
Yes
(INC) Item Name Code
00335
Date
Tue, Jan 1, 1963
Schedule B Code
9030330080
Body Diameter
3.630 inches nominal
Cooling Method
self-cooled
Frequency Range Rating
+0.000 to 3.000 gigahertz
Operating Position
horizontal
Overall Height
3.200 inches minimum and 3.240 inches maximum
Overall Length
13.940 inches minimum and 14.060 inches maximum
Overall Width
4.730 inches minimum and 4.770 inches maximum
Power Rating
2.500 kilowatts average and 3.200 megawatts peak
Style Designator
flange, without fins
Termination Type
waveguide flange
Voltage Standing Wave Ratio
1.10
Voltage Standing Wave Ratio Frequency Range
+0.000 to 3.000 gigahertz

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000335

Cross Reference

CAGE Codes

05869
Raytheon Company Div Rmd Strategic
U.s./canadian manufacturers
82577
Raytheon Company Dba Raytheon
Non-manufacturers
00929
Microlab/fxr Llc
U.s./canadian manufacturers
92947
Ertel Mfg Corp
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34580
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061700

Schedule B & Trade

Schedule B
9030-33-0080
Description
instruments and apparatus for measuring or checking power, without a recording device, nesoi
End Use
21160 - Measuring, testing, control instruments
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87475
(NAICS) North American Industrial Classification System
334515

Questions & Answers

  1. What is the FSCG of the NSN 5985-00-080-1382?

    The FSCG of the NSN 5985-00-080-1382 is 5985

  2. Does the NSN 5985-00-080-1382 have a Schedule B code assigned?

    Yes, the Schedule B code is 9030330080

  3. Does NSN 5985-00-080-1382 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5985-00-080-1382 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5985-00-080-1382 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5985-00-080-1382 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.