1. Home /
  2. FSC NSN Catalog /
  3. Capacitors /
  4. 72F6801FC

NSN 72F6801FC

Plastic Dielectr Fixed Capacitor

w/o mtg facilities, terminal(s) on one surface body style, 4.562 inches nominal body length, 8.000 inches nominal body height, 2.875 inches nominal body width, 25.000 microfarads single section capacitance value per section.

NSN 5910-01-013-2361 Datasheet

(NSN) National Stock Number
5910-01-013-2361
(FSC) Federal Supply Classification
5910 - Capacitors
(NIIN) National Item Identification Number
01-013-2361
Requires Demilitarization
Yes
(INC) Item Name Code
00006
Date
Thu, Nov 27, 1975
Schedule B Code
8532250080
Body Height
8.000 inches nominal
Body Length
4.562 inches nominal
Body Style
w/o mtg facilities, terminal(s) on one surface
Body Width
2.875 inches nominal
Capacitance Value Per Section
25.000 microfarads single section
Center To Center Distance Between Terminals Parallel To Length
1.250 inches minimum and 2.000 inches maximum
Dissipation Factor At Reference Temp In Percent
0.1000
Insulation Resistance At Reference Temp
50000.0 megohm-microfarads
Nonderated Operating Temp
-55.0 celsius minimum and 125.0 celsius maximum
Nonderated Continuous Voltage Rating And Type Per Section
900.0 ac-rms single section
Reliability Indicator
not established
Schematic Diagram Designator
no common or grounded electrode(s)
Terminal Diameter
0.375 inches nominal
Terminal Height From Body
0.875 inches nominal
Terminal Type And Quantity
2 standoff, threaded stud
Tolerance Range Per Section
-10.00 to 10.00 percent single section

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000006

Cross Reference

CAGE Codes

04801
L3harris Maritime Power & Energy Solutions, Inc
U.s./canadian manufacturers
01002
General Electric Co Capacitors Div
U.s./canadian manufacturers
93790
Cornell-Dubilier Electronics, Inc.
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
P - 77.5
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34450
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
061400

Schedule B & Trade

Schedule B
8532-25-0080
Description
fixed capacitors, dielectric of paper or plastic, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77866
(NAICS) North American Industrial Classification System
334416

Questions & Answers

  1. What is the FSCG of the NSN 5910-01-013-2361?

    The FSCG of the NSN 5910-01-013-2361 is 5910

  2. Does the NSN 5910-01-013-2361 have a Schedule B code assigned?

    Yes, the Schedule B code is 8532250080

  3. Does NSN 5910-01-013-2361 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5910-01-013-2361 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5910-01-013-2361 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5910-01-013-2361 was assigned to the Federal Catalog?

    It was assigned 50 years ago, on Thu, Nov 27, 1975

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.