NSN 7907296

Signal Generator

A grouping of two or more physically connected or related electrical an/or electronic parts capable of dissassemblage. Each component of the assemblage must be capable of functioning in accordance with its own item name. Consists of a single printed circuit board or terminal board upon which are mounted separately manufactured electronic components such as capacitors, inductors, resistors, and the like. It may also include printed electronic components. The item is generally part of a subassembly and cannot be assigned a more definite item name. For items having a complete individual electrical/electronic function, use applicable item name such as amplifier (as modified); power supply; or the like. For items not having a complete individual electrical/electronic function, see applicable subassembly name, such as amplifier subassembly; power supply subassembly; or the like. For an assembly of electrical/electronic components mounted on other than a single printed wiring board, see electronic components assembly. Excludes:printed circuit board

7.000 inches nominal overall height, single phase, rack mounting type, 60.0 hertz nominal frequency rating, 14.250 inches nominal overall length.

NSN 6625-00-826-7450 Datasheet

(NSN) National Stock Number
6625-00-826-7450
(NIIN) National Item Identification Number
00-826-7450
Requires Demilitarization
Yes
(INC) Item Name Code
03901
Date
Fri, Jan 1, 1960
Schedule B Code
8543200000
Frequency Rating
60.0 hertz nominal
Phase
single
Mounting Type
rack
Overall Height
7.000 inches nominal
Overall Length
14.250 inches nominal
Overall Width
19.000 inches nominal
Special Features
used with 738ar & 739ar
Voltage Rating
110.0 volts nominal

Identification

Demilitarization Code
D - Usml or ccl military items - demil required. Destroy item and components to prevent restoration or repair to a usable condition. (note 5).
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
XZZ -
Pseudo Item Name Code
0003901

Cross Reference

CAGE Codes

28480
Hewlett-Packard Company Dba Hp
U.s./canadian manufacturers
19200
Combat Capabilities Development Command (ccdc) Armaments Center Dba Ccdc Div Logistics Research and Engineering Directorate
Government departments or units, including military organizations

Freight Information

Air Commodity
HQ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Less than Carload Rating
P - 77.5
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34580
Water Commodity
738 - Computing equipment, computer components, and circuit cards
National Motor Freight Classification Item Number
061700

Schedule B & Trade

Schedule B
8543-20-0000
Description
signal generators
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77878
(NAICS) North American Industrial Classification System
334515

Questions & Answers

  1. What is the FSCG of the NSN 6625-00-826-7450?

    The FSCG of the NSN 6625-00-826-7450 is 6625

  2. Does the NSN 6625-00-826-7450 have a Schedule B code assigned?

    Yes, the Schedule B code is 8543200000

  3. Does NSN 6625-00-826-7450 require demilitarization?

    Usml or ccl military items - demil required. Destroy item and components to prevent restoration or repair to a usable condition. (note 5).

  4. Does NSN 6625-00-826-7450 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6625-00-826-7450 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 6625-00-826-7450 was assigned to the Federal Catalog?

    It was assigned 66 years ago, on Fri, Jan 1, 1960

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 4 hours ago
View History