  4. 8080TNCF

NSN 8080TNCF

Electrical Dummy Load

An item consisting of two or more of the following components: stem, rivet body, sleeve, expander, bolt, and collar. It is a headed fastening device with the shank designed to be expanded by means of a separate or integral stem or mandrel, or bolt and expander. It is designed to be installed or expanded from one side only. Excludes:nut, blind assembly.

female connector end design, 50.0 nominal impedance rating in ohms, tnc coaxial connector series designation, self-cooled cooling method, +0.000 to 3.500 gigahertz frequency range rating.

NSN 5985-00-033-3996 Datasheet

(NSN) National Stock Number
5985-00-033-3996
(FSC) Federal Supply Classification
5985 - Related Equipment, Waveguides and Antennas
(NIIN) National Item Identification Number
00-033-3996
Requires Demilitarization
Yes
(INC) Item Name Code
00335
Date
Fri, Nov 3, 1972
Schedule B Code
9030330080
Coaxial Connector Series Designation
tnc
Connector End Design
female
Cooling Method
self-cooled
Frequency Range Rating
+0.000 to 3.500 gigahertz
Impedance Rating In Ohms
50.0 nominal
Operating Position
all positions
Overall Height
1.250 inches nominal
Overall Length
5.125 inches nominal
Overall Width
1.250 inches nominal
Power Rating
25.000 watts average
Special Features
5.000 in lg,1.250 in w,1.250 in h
Style Designator
coaxial mounted
Termination Type
connection coaxial
Voltage Standing Wave Ratio
1.25
Voltage Standing Wave Ratio Frequency Range
+0.000 to 3.500 gigahertz

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000335

Cross Reference

CAGE Codes

70998
Bird Electronic Corporation Div Bird Electronic Corp
U.s./canadian manufacturers
65597
"thales Usa, Inc. Div Air Mobility Solutions ("ams")"
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35120
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
062920

Schedule B & Trade

Schedule B
9030-33-0080
Description
instruments and apparatus for measuring or checking power, without a recording device, nesoi
End Use
21160 - Measuring, testing, control instruments
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87475
(NAICS) North American Industrial Classification System
334515

Questions & Answers

  1. What is the FSCG of the NSN 5985-00-033-3996?

    The FSCG of the NSN 5985-00-033-3996 is 5985

  2. Does the NSN 5985-00-033-3996 have a Schedule B code assigned?

    Yes, the Schedule B code is 9030330080

  3. Does NSN 5985-00-033-3996 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5985-00-033-3996 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5985-00-033-3996 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5985-00-033-3996 was assigned to the Federal Catalog?

    It was assigned 53 years ago, on Fri, Nov 3, 1972

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.