1. Home /
  2. FSC NSN Catalog /
  3. Switches /
  4. 837-A5

NSN 837-A5

Thermostatic Switch

An item specifically designed to be placed around that portion of a connector,receptable,electrical or connector,plug,electrical which contains the facilities for attaching wires or cables. It may be designed to provide the nesessary accomodations between an electrical cable clamping device and an electrical connector shell or it may include the clamping device. It may be used for shielding against electrical interference, mechanical injury or physical damage due to environmental conditions.

3.750 inches nominal bulb length, increase contact action stimulus, 0.375 inches nominal bulb diameter, 72.0 inches nominal capillary tube length, 3.500 inches nominal body height.

NSN 5930-01-035-8830 Datasheet

(NSN) National Stock Number
5930-01-035-8830
(FSC) Federal Supply Classification
5930 - Switches
(NIIN) National Item Identification Number
01-035-8830
Requires Demilitarization
Yes
(INC) Item Name Code
00451
Date
Thu, Feb 17, 1977
Schedule B Code
9032100000
Body Height
3.500 inches nominal
Bulb Diameter
0.375 inches nominal
Bulb Length
3.750 inches nominal
Capillary Tube Length
72.0 inches nominal
Contact Action Stimulus
increase
Contact Adjustability
actuation point adjustable and deactuation point adjustable
Contact Adjustment Type
external actuation point screw and external deactuation point screw
Contact Adjustment Range
+130.00 to 200.00 actuation point degrees fahrenheit and +130.00 to 200.00 deactuation point degrees fahrenheit
Contact Load Current Rating
unable to decode
Contact Voltage Rating In Volts
unable to decode
Features Provided
tubing end seal connection
Media For Which Designed
gas or liquid
Mounting Method
base
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
Operating Temp Rating
240.0 fahrenheit maximum
Overall Height
4.188 inches nominal
Overall Length
1.875 inches nominal
Overall Width
2.594 inches nominal
Style Designator
rectangular
Temp Sensing Element Type
capillary tube-bulb
Terminal Type
tab w/screw

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000451

Cross Reference

CAGE Codes

01121
Rockwell Automation, Inc.
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
9032-10-0000
Description
thermostats
End Use
21160 - Measuring, testing, control instruments
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87461
(NAICS) North American Industrial Classification System
334512

Questions & Answers

  1. What is the FSCG of the NSN 5930-01-035-8830?

    The FSCG of the NSN 5930-01-035-8830 is 5930

  2. Does the NSN 5930-01-035-8830 have a Schedule B code assigned?

    Yes, the Schedule B code is 9032100000

  3. Does NSN 5930-01-035-8830 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5930-01-035-8830 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5930-01-035-8830 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5930-01-035-8830 was assigned to the Federal Catalog?

    It was assigned 49 years ago, on Thu, Feb 17, 1977

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 1 day ago
View History