Electrical Dummy Load

forced air cooling method, all positions operating position, 5.850 inches nominal overall length, 3.240 inches maximum overall height, -54.0 celsius and 140.0 celsius ambient temp at full rated power.

NSN 5985-01-082-2867 Datasheet

(NSN) National Stock Number
5985-01-082-2867
(FSC) Federal Supply Classification
5985 - Related Equipment, Waveguides and Antennas
(NIIN) National Item Identification Number
01-082-2867
Requires Demilitarization
Yes
(INC) Item Name Code
00335
Date
Thu, Aug 30, 1979
Schedule B Code
9030330080
Ambient Temp At Full Rated Power
-54.0 celsius and 140.0 celsius
Cooling Method
forced air
Operating Position
all positions
Overall Height
3.240 inches maximum
Overall Length
5.850 inches nominal
Overall Width
3.300 inches maximum
Power Rating
223.000 watts peak and 125.000 watts average
Style Designator
waveguide mounted
Termination Type
waveguide flange
Voltage Standing Wave Ratio
1.10
Voltage Standing Wave Ratio Frequency Range
+440.000 to 500.000 hertz
Waveguide Flange Designation
ug1666/u

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000335

Cross Reference

CAGE Codes

A0810
Leonardo S.p.a. Div Electronics
Non-us manufacturer (nato), other foreign organization or codification bureaus
96214
Raytheon Company Dba Raytheon
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Less than Carload Rating
W - Rating variable
National Motor Freight Class Rating
W - Rating variable
Rail Variation
1
Special Handling
5 - Low sensitivity, category iv, aa&e, unclassified
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35120
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
062920

Schedule B & Trade

Schedule B
9030-33-0080
Description
instruments and apparatus for measuring or checking power, without a recording device, nesoi
End Use
21160 - Measuring, testing, control instruments
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87475
(NAICS) North American Industrial Classification System
334515

Questions & Answers

  1. What is the FSCG of the NSN 5985-01-082-2867?

    The FSCG of the NSN 5985-01-082-2867 is 5985

  2. Does the NSN 5985-01-082-2867 have a Schedule B code assigned?

    Yes, the Schedule B code is 9030330080

  3. Does NSN 5985-01-082-2867 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5985-01-082-2867 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5985-01-082-2867 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5985-01-082-2867 was assigned to the Federal Catalog?

    It was assigned 47 years ago, on Thu, Aug 30, 1979