Circuit Breaker

Model / MPN: 860028-8 | NSN: 5925-00-051-4889
ITAR Registered seal

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

Product Details
NATO Stock Number
5925-00-051-4889
Sold in multiples of
1 EA
DEMIL
NO
Body Length
Between 2.490 inches and 2.510 inches
Body Width
Between 0.740 inches and 0.760 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
Between 1.180 inches and 1.200 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 1.802 inches and 1.822 inches
Fragility Factor
Moderately rugged
Mounting Surface To Terminal End Distance
Between 1.990 inches and 2.010 inches
Pole Quantity
1
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Magnetic-hydraulic single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Internal Trip Release Configuration
Series trip single location
Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
19.000 at 200 pct single location and 65.000 at 200 pct single location
Inclosure Protection Type For Which Designed
Explosion proof and fungus resistant and moisture resistant and vibrationproof
Frequency In Hertz
400.0 single location
Thread Series Designator
Unc
Terminal Type And Quantity
2 screw

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
860028-8 Cross Reference
  • 860028-8
  • 74-106-1
  • DMS 83059B
  • DMS83059