1. Home /
  2. FSC NSN Catalog /
  3. Switches /
  4. 9126543

NSN 9126543

Sensitive Switch

A definite continuous length of cable,special purpose,electrical, having one or more ends processed or terminated in fittings which provide for connectionn to other items. For items which the rated working is 300 volts or more, see: cable assembly,power,electrical. Excludes items having branches or forks. Excludes: lead,test and cable and conduit assembly,electrical.

0.004 pretravel inches maximum and 0.005 overtravel inches minimum and 0.004 differential inches maximum actuator movement, leaf actuator style, 0.0570 inches minimum and 0.067 inches maximum actuator free position height, 0.093 inches minimum and 0.125 inches maximum actuator length, pushbutton actuator adapter style.

NSN 5930-00-578-2000 Datasheet

(NSN) National Stock Number
5930-00-578-2000
(FSC) Federal Supply Classification
5930 - Switches
(NIIN) National Item Identification Number
00-578-2000
Requires Demilitarization
Yes
(INC) Item Name Code
00399
Date
Tue, Jan 1, 1963
Schedule B Code
8536509050
Actuator Length
0.093 inches minimum and 0.125 inches maximum
Actuator Movement
0.004 pretravel inches maximum and 0.005 overtravel inches minimum and 0.004 differential inches maximum
Actuator Adapter Style
pushbutton
Actuator Free Position Height
0.0570 inches minimum and 0.067 inches maximum
Actuator Style
leaf
Actuator Width
0.546 inches minimum and 0.578 inches maximum
Body Length
0.807 inches minimum and 0.817 inches maximum
Body Width
0.422 inches minimum and 0.454 inches maximum
Body Style
hole mounted
Center To Center Distance Between Mounting Facilities Parallel To Length
0.572 inches minimum and 0.630 inches maximum
Contact Load Current Rating At Maximum Rated Voltage
5.000 amperes resistive dc and 3.000 amperes inductive dc and 5.000 amperes resistive ac
Inclosure Type
fully inclosed
Maximum Voltage Rating In Volts
250.0 ac and 30.0 dc
Mounting Method
unthreaded hole(s)
Nominal Thread Size
0.469 inches
Nonpile-Up Contact Arrangement
unable to decode
Switch Release Force
1.0 ounces minimum
Switch Actuating Force
32.0 ounces maximum
Terminal Type And Quantity
3 tab, solder lug
Thread Quantity Per Inch
32
Thread Series Designator
uns
Unthreaded Mounting Hole Diameter
0.053 inches minimum and 0.063 inches maximum

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000399

Cross Reference

CAGE Codes

A486G
Nimikkeistokeskus Ncb Finland
Government departments or units, including military organizations
97403
Cecom Lr Center
U.s./canadian manufacturers
91920
Marshall Industries Claude Michael Group
U.s./canadian manufacturers
91929
Honeywell International Inc. Dba Honeyweel Sensing & Controls
U.s./canadian manufacturers
K6596
Honeywell Control Systems Ltd
Non-us manufacturer (nato), other foreign organization or codification bureaus
U4042
Honeywell Control Systems Ltd Div Automation & Control Solutions - Service
Non-us manufacturer (nato), other foreign organization or codification bureaus
28528
Itt Industries Inc Itt Aerospace Communications Div East
U.s./canadian manufacturers
31550
L3harris Technologies, Inc. Dba Harris Corporation
U.s./canadian manufacturers
C0426
Hensoldt Sensors Gmbh
Non-us manufacturer (nato), other foreign organization or codification bureaus
9F512
Parker-Hannifin Corporation Dba Pneutronics Div Hydraulic Pump Division
U.s./canadian manufacturers
18876
Us Army Aviation and Missile Command
Government departments or units, including military organizations
66717
Wurlitzer Co the
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-50-9050
Description
switches, slide, for a voltage not exceeding 1,000 v
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77255
(NAICS) North American Industrial Classification System
335931

Questions & Answers

  1. What is the FSCG of the NSN 5930-00-578-2000?

    The FSCG of the NSN 5930-00-578-2000 is 5930

  2. Does the NSN 5930-00-578-2000 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536509050

  3. Does NSN 5930-00-578-2000 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5930-00-578-2000 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5930-00-578-2000 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5930-00-578-2000 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 9 hours ago
View History