Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.

Q & A

Part number APGH96661REC4218636
What are the historical prices for part number APGH9666-1REC4-21863-6?
No pre-dated pricing for this NSN could be found.
Does this part number APGH9666-1REC4-21863-6 have a shelf life?
No. There is no shelf life applicable for this part.
Does this part number APGH9666-1REC4-21863-6 require Demilitarization?
Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9).
Is part number APGH9666-1REC4-21863-6 ITAR controlled?
No. This item is not ITAR Controlled.
What is the NSN for part number APGH9666-1REC4-21863-6?
5925-01-262-6151
Who are the manufacturers of APGH9666-1REC4-21863-6 and NSN 5925-01-262-6151?
  • Northrop Grumman Systems Corporation (CAGE 18323)
  • Sensata Technologies Maryland, Inc (CAGE 81541)

APGH9666-1REC4-21863-6

Description: Circuit Breaker
Part Number APGH9666-1REC4-21863-6 APGH9666 1REC4 21863 6

Specification

Thread Size: 9/64"

AAQL Body Style
Multipole-multiple actuator type
ADAQ Body Length
2.000 inches
ADAT Body Width
3.015 inches maximum
ADTV Case Material
Plastic
AEBP Center To Center Distance Between Terminals Parallel To Length
1.560 inches
AEBQ Center To Center Distance Between Terminals Parallel To Width
0.750 inches
AEBY Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches
AEGJ Switch Contact Arrangement
Single pole, double throw
AEHA Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches
AJEC Boss Height
0.130 inches
AJWX Mounting Surface To Terminal End Distance
2.032 inches maximum
AKPX Pole Quantity
4
AXHR Mounting Facility Type And Quantity
8 threaded hole
BBRG Storage Type
General purpose warehouse
CMLP Thready Qty Per Inch (tpi)
32
CPLM Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac third location
CPLM Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac second location
CPRF Operating Voltage Type And Rating Per Pole In Volts
240.0 ac fourth location and 65.0 dc fourth location
CPRF Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location
CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location
CPRH Circuit Protection Type
Overcurrent all locations
CPRJ Trip Release Method
Magnetic all locations
CPRL Trip Release Characteristic
Time delay all locations
CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
CPRQ Reset Method
Manual
CPRR Main Contact Tripping Mechanism Type
Trip free
CPRT Manual Actuator Type And Quantity
4 toggle
CPRW Actuator Function
Trip-reset
CPRX Actuator Position Designation
At each pole
CPRY External Actuator Linkage Arrangement
One, two, three, and four linked
CPRZ Auxiliary Switch Function And Quantity
1 alarm
CPSM Internal Trip Release Configuration
Series trip first location
CPSM Internal Trip Release Configuration
Series trip third location
CQJX Nominal Thread Size
0.138 inches
CQSM Switch Location And Position Designation
Internal at pole one
CQWN Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct all locations and 1.900 maximum at 200 pct all locations
CQXF Inclosure Protection Type For Which Designed
Moisture resistant and shock resistant and vibration resistant
CRTK Switch Terminal Type
Tab, solder lug
CSSX Switch Current Rating And Type In Amps
5.0 ac and 5.0 dc
CSWP Switch Voltage Rating And Type In Volts
240.0 ac and 50.0 dc
FREQ Frequency In Hertz
400.0 all locations
TEST Test Data Document
18323-7489a63 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
THSD Thread Series Designator
Unc
TTQY Terminal Type And Quantity
10 tab w/screw