1. Home /
  2. FSC NSN Catalog /
  3. Filters and Networks /
  4. A6352

NSN A6352

Radio Frequency Interfere Filter

0.690 inches maximum body outside diameter, metal body material, nut and washer features provided, unable to decodeunable to decode functional terminal type and quantity, hermetically sealed inclosure type.

NSN 5915-01-106-7902 Datasheet

(NSN) National Stock Number
5915-01-106-7902
(FSC) Federal Supply Classification
5915 - Filters and Networks
(NIIN) National Item Identification Number
01-106-7902
Requires Demilitarization
Yes
(INC) Item Name Code
00765
Date
Sun, Jan 25, 1981
Schedule B Code
8527995030
Body Material
metal
Body Outside Diameter
0.690 inches maximum
Features Provided
nut and washer
Functional Terminal Type And Quantity
unable to decodeunable to decode
Inclosure Type
hermetically sealed
Load Impedance Per Function
50.0 ohms blank
Mounting Facility Screw Thread Series Designator
unf
Mounting Facility Type And Quantity
1 threaded bushing
Nominal Thread Size
0.312 inches
Operating Current Rating Per Function In Amps
3.0 blank
Operating Voltage Rating And Type Per Function
240.0 volts ac blank
Operating Temp Range
-55.0 to 125.0 celsius
Overall Length
1.725 inches nominal
Power Line Frequency Rating Per Function In Hertz
400.0 blank
Principal Circuitry Type Per Function
inductance-capacitance blank
Source Impedance Rating Per Function
50.0 ohms blank
Style Designator
round terminal/terminals on opposite surfaces

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000765

Cross Reference

CAGE Codes

D9853
Rockwell Collins Deutschland Gmbh Div Rockwell Collins International & Service Solutions
Non-us manufacturer (nato), other foreign organization or codification bureaus
0LSP2
Spectrum Control, Inc.
U.s./canadian manufacturers
33095
Spectrum Control Inc
U.s./canadian manufacturers
50464
Hq Electronic Systems Div Air Force Systems Command
U.s./canadian manufacturers
12294
Murata Erie North America Inc Divof Murata Erie
U.s./canadian manufacturers
F0052
Thales Dms France Sas
Non-us manufacturer (nato), other foreign organization or codification bureaus
05584
Autodyne Manufacturing Co Inc
U.s./canadian manufacturers
59901
Mtk Electronics Inc
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
P - 77.5
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
58500
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
061990

Schedule B & Trade

Schedule B
8527-99-5030
Description
reception apparatus, nesoi
End Use
41210 - Stereo equipment, etc.
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
76289
(NAICS) North American Industrial Classification System
334310

Questions & Answers

  1. What is the FSCG of the NSN 5915-01-106-7902?

    The FSCG of the NSN 5915-01-106-7902 is 5915

  2. Does the NSN 5915-01-106-7902 have a Schedule B code assigned?

    Yes, the Schedule B code is 8527995030

  3. Does NSN 5915-01-106-7902 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5915-01-106-7902 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5915-01-106-7902 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5915-01-106-7902 was assigned to the Federal Catalog?

    It was assigned 45 years ago, on Sun, Jan 25, 1981

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability