NSN AM4-A8A2A2A18-A

Circuit Breaker

2.500 inches nominal body length, 2 alarm auxiliary switch function and quantity, magnetic blowout arc quenching method, at each pole actuator position designation, trip-reset actuator function.

NSN 5925-01-153-7491 Datasheet

(NSN) National Stock Number
5925-01-153-7491
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-153-7491
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Mon, May 16, 1983
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at each pole
Arc Quenching Method
magnetic blowout
Auxiliary Switch Function And Quantity
2 alarm
Body Length
2.500 inches nominal
Body Style
multipole-multiple actuator type
Body Width
2.060 inches minimum and 2.070 inches maximum
Boss Height
0.140 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Circuit Protection Type
overcurrent first location
Circuit Protection Type
overcurrent second location
Circuit Protection Type
overcurrent third location
Circuit Protection Type
undervoltage fourth location
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
External Actuator Linkage Arrangement
one, two, three, and four linked
Fragility Factor
moderately rugged
Frequency In Hertz
50.0 or 60.0 first location
Frequency In Hertz
50.0 or 60.0 second location
Frequency In Hertz
50.0 or 60.0 third location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Internal Trip Release Configuration
relay trip fourth location
Internal Trip Release Configuration
series trip second location
Internal Trip Release Configuration
series trip third location
Internal Trip Release Configuration
series trip first location
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
4 toggle
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc fourth location
Mounting Facility Type And Quantity
8 threaded hole(s)
Mounting Surface To Terminal End Distance
2.409 inches minimum and 2.533 inches maximum
Nominal Thread Size
0.138 inches
Operating Voltage Type And Rating Per Pole In Volts
102.0 dc fourth location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
Pole Quantity
4
Reset Method
manual
Special Handling Feature
magnetic
Storage Type
general purpose warehouse
Switch Location And Position Designation
internal at pole two and internal at pole three
Switch Terminal Type
tab, solder lug
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
Switch Contact Arrangement
double pole, double throw
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc
Terminal Type And Quantity
8 threaded stud
Thread Quantity Per Inch
32
Thread Series Designator
unified national coarse (unc)
Trip Release Characteristic
instantaneous fourth location
Trip Release Characteristic
time delay first location
Trip Release Characteristic
time delay second location
Trip Release Characteristic
time delay third location
Trip Release Method
magnetic-hydraulic all locations
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 11.000 maximum at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 11.000 maximum at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 11.000 maximum at 200 pct third location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Unpackaged Unit Weight
12.500 ounces nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

98230
National Security Agency
U.s./canadian manufacturers
74193
Eaton Corp Heinemann Products Commercial Controls Div
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-153-7491?

    The FSCG of the NSN 5925-01-153-7491 is 5925

  2. Does the NSN 5925-01-153-7491 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-153-7491 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-153-7491 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-153-7491 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-153-7491 was assigned to the Federal Catalog?

    It was assigned 43 years ago, on Mon, May 16, 1983

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.