  4. AP112-2833-2

NSN AP112-2833-2

Circuit Breaker

A single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. It may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. Refers to bulk quantities only. For items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see wire,(as modified), includes litz wire and insulated/uninsulated armored, and ground wire. Excludes:braid, wire; fuse wire; resistance wire and magnet wire.

1.937 inches maximum body width, multipole-single actuator type body style, at pole two actuator position designation, trip-reset actuator function, 1.562 inches maximum body length.

NSN 5925-01-028-0806 Datasheet

(NSN) National Stock Number
5925-01-028-0806
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-028-0806
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Fri, Sep 24, 1976
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Body Length
1.562 inches maximum
Body Style
multipole-single actuator type
Body Width
1.937 inches maximum
Bushing Length
0.380 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
Circuit Protection Type
overcurrent all locations
Fragility Factor
moderately rugged
Frequency In Hertz
50.0 or 60.0 all locations
Inclosure Protection Type For Which Designed
hermetically sealed and shockproof and vibrationproof
Internal Trip Release Configuration
series trip all locations
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac third location
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Mounting Facility Type And Quantity
1 threaded bushing with panel seal
Mounting Surface To Terminal End Distance
1.780 inches maximum
Nominal Thread Size
0.375 inches
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Pole Quantity
3
Reset Method
manual
Special Handling Feature
magnetic
Storage Type
general purpose warehouse
Terminal Type And Quantity
6 wire hook
Thread Pitch Diameters
+0.3503 to 0.3537 inches
Thread Quantity Per Inch
32
Thread Series Designator
unef
Trip Delay Time In Seconds Per Rated Continuous Current
0.070 minimum at 200 pct and 0.700 maximum at 200 pct all locations
Trip Release Characteristic
time delay all locations
Trip Release Method
magnetic all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Unpackaged Unit Weight
5.400 ounces nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

1VPW8
General Dynamics Mission Systems, Inc. Dba Gdms
U.s./canadian manufacturers
94990
Motorola Inc. Dba Integrated Information Systems Group
U.s./canadian manufacturers
81541
Sensata Technologies Maryland, Inc
Non-manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-028-0806?

    The FSCG of the NSN 5925-01-028-0806 is 5925

  2. Does the NSN 5925-01-028-0806 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-028-0806 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-028-0806 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-028-0806 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-028-0806 was assigned to the Federal Catalog?

    It was assigned 50 years ago, on Fri, Sep 24, 1976