1. Home /
  2. FSC NSN Catalog /
  3. Supplies, Equipment and Medical and Surgical Instruments /
  4. BD309593

NSN BD309593

Sa Hypodermic Syringe and Needle

A straight, hollow product, welded or seamless, of round, square, or any other cross section and continuous periphery, which does not conform in cross sectional dimensions to recognized pipe standards. It is designed to convey fluids, gasses, and/or semisolids. It may be rolled into coils for ease in handling. For items designed to join a tube or tube fitting to another tube, pipe, or hose or fitting, see adapter (as modified); couplig (as modified); or nipple (as modified). Excludes: tube,bent (as modified); pipe,metallic; spacer sleeve; metal bar (hollow); and items with fitting, except end protectors.

syringe & ndl hypodermic safety 3ml 22gax1.5in pyrogen free 800s part name assigned by controlling agency, not provided needle hub, 22 needle gage number, 3.0 cubic centimeters capacity, 1.500 inches nominal cannula length.

NSN 6515-01-413-3145 Datasheet

(NSN) National Stock Number
6515-01-413-3145
(NIIN) National Item Identification Number
01-413-3145
Requires Demilitarization
Yes
(INC) Item Name Code
51637
Date
Wed, May 10, 1995
Schedule B Code
9018310040
Cannula Length
1.500 inches nominal
Capacity
3.0 cubic centimeters
Part Name Assigned By Controlling Agency
syringe & ndl hypodermic safety 3ml 22gax1.5in pyrogen free 800s
Needle Hub
not provided
Needle Gage Number
22
Scale Smallest Increment
0.100 cubic centimeters
Special Features
clean; pyrogen-free; plastic luer-lock hypodermic safety syringe; 3 ml, 22 gage by 1-1/2 in. (3.8 cm) long detachable needle; barrel made of transparent plastic; calibrated to 3 ml; w/main graduations numbered at each 0.5 ml; sub-graduations slash marked each 0.1 ml; protective shield to prevent neelde sticks and guard against infection by hiv and hepatitis; the barrel terminates in a finger grip oria knob; the plunger is made of plastic

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Pseudo Item Name Code
0051637

Cross Reference

CAGE Codes

06531
Becton, Dickinson and Co Dba Becton Dickinson & Co
U.s./canadian manufacturers
89875
Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia
U.s./canadian manufacturers
2T036
Krasity's Medical & Surgical Supply, Inc. Dba Krasity's
Non-manufacturers

Freight Information

Air Commodity
MZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
00000
Water Commodity
534 - Medical supplies (room temperature) (not requiring temperature control)
National Motor Freight Classification Item Number
056590

Schedule B & Trade

Schedule B
9018-31-0040
Description
hypodermic syringes, with or without their needles
End Use
21610 - Medicinal equipment
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87221
(NAICS) North American Industrial Classification System
339112

Questions & Answers

  1. What is the FSCG of the NSN 6515-01-413-3145?

    The FSCG of the NSN 6515-01-413-3145 is 6515

  2. Does the NSN 6515-01-413-3145 have a Schedule B code assigned?

    Yes, the Schedule B code is 9018310040

  3. Does NSN 6515-01-413-3145 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6515-01-413-3145 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6515-01-413-3145 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 6515-01-413-3145 was assigned to the Federal Catalog?

    It was assigned 31 years ago, on Wed, May 10, 1995

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.