1. Home /
  2. FSC NSN Catalog /
  3. Supplies, Equipment and Medical and Surgical Instruments /
  4. C1606AK3

NSN C1606AK3

Intravenous Catheterization Kit

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

25 ga. x 1.59 cm skin wheal needle 1; 22 ga. x 3.81 cm vessel locating needle 1; 18 ga. x 6.35 cm polytetrafluoroethylene radiopaque catheter over 20ga.introducer needle 1; 18 ga. x 6.35 cm thinwall needle 1; 5cc syringe 2; 5cc lidocaine hci 1% ampule 1; 40 cm long stainless steel guidewire with 3mm j-tip with straight other end, flexible with 0.89 mm diameter 1; disposable scapel 1; silk suture with curved needle 1; providone - iodine swabsticks 3; 5.08 cm x 5.08 cm guaze pads 2; 10.16 cm x 10.16 cm gauze pads 4; csr wrap 1;fenestrated drape 1; 4.4 cm filter straw 1; 16 ga. x 20.32cm.radio paque catheter 1; disposable hemostate 1; 7 fr.vein dilator 1; 16 ga. x 40.64 cm. catheter1;0.89 mm j-tip guide wire 1; hemostat 1; curved suture needle 1 nonsupply items and quantities, disposable disposition after initial use, 28 component quantity, industrial component document origin, c1606ak3 model number.

NSN 6515-01-383-4146 Datasheet

(NSN) National Stock Number
6515-01-383-4146
(NIIN) National Item Identification Number
01-383-4146
Requires Demilitarization
Yes
(INC) Item Name Code
48393
Date
Wed, Nov 24, 1993
Schedule B Code
9018390030
Component Document Origin
industrial
Component Quantity
28
Disposition After Initial Use
disposable
Model Number
c1606ak3
Nonsupply Items And Quantities
25 ga. x 1.59 cm skin wheal needle 1; 22 ga. x 3.81 cm vessel locating needle 1; 18 ga. x 6.35 cm polytetrafluoroethylene radiopaque catheter over 20ga.introducer needle 1; 18 ga. x 6.35 cm thinwall needle 1; 5cc syringe 2; 5cc lidocaine hci 1% ampule 1; 40 cm long stainless steel guidewire with 3mm j-tip with straight other end, flexible with 0.89 mm diameter 1; disposable scapel 1; silk suture with curved needle 1; providone - iodine swabsticks 3; 5.08 cm x 5.08 cm guaze pads 2; 10.16 cm x 10.16 cm gauze pads 4; csr wrap 1;fenestrated drape 1; 4.4 cm filter straw 1; 16 ga. x 20.32cm.radio paque catheter 1; disposable hemostate 1; 7 fr.vein dilator 1; 16 ga. x 40.64 cm. catheter1;0.89 mm j-tip guide wire 1; hemostat 1; curved suture needle 1
Special Features
individually packed kits; 10 kits per package
Sterility
sterile
Unit Package Quantity
10

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Pseudo Item Name Code
0048393

Cross Reference

CAGE Codes

11171
B. Braun Medical Inc
U.s./canadian manufacturers

Freight Information

Schedule B & Trade

Schedule B
9018-39-0030
Description
bougies, catheters, drains and sondes and parts and accessories
End Use
21610 - Medicinal equipment
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87221
(NAICS) North American Industrial Classification System
339112

Questions & Answers

  1. What is the FSCG of the NSN 6515-01-383-4146?

    The FSCG of the NSN 6515-01-383-4146 is 6515

  2. Does the NSN 6515-01-383-4146 have a Schedule B code assigned?

    Yes, the Schedule B code is 9018390030

  3. Does NSN 6515-01-383-4146 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6515-01-383-4146 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6515-01-383-4146 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 6515-01-383-4146 was assigned to the Federal Catalog?

    It was assigned 32 years ago, on Wed, Nov 24, 1993

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.