1. Home /
  2. FSC NSN Catalog /
  3. Nonrotating Electrical Converters /
  4. C8987PT4

NSN C8987PT4

Metallic Rectifier Assembly

Two or more individual fixed, variable, thermal, or adjustable resistors on a common mounting or mounted on each other. The resistors must be separable and each must be capable of functioning in accordance with its applicable item name. For variable resistors mounted in tandem with a common or dual concentric shaft, see resistor, variable (as modified) and attenuator, variable. For inseparable resistors permanently cased, sealed or potted together to form a multisection unit, see resistor assortment; resistor set, matched; and items which have wire leads temporarily twisted together, or are otherwise physically attached solely for convenience in handling or shipping.

not included grounding provision, 2 individual circuit connection quantity, resistive load type, selenium rectifying material, doubler circuit type.

NSN 6130-00-028-6911 Datasheet

(NSN) National Stock Number
6130-00-028-6911
(FSC) Federal Supply Classification
6130 - Nonrotating Electrical Converters
(NIIN) National Item Identification Number
00-028-6911
Requires Demilitarization
Yes
(INC) Item Name Code
20974
Date
Tue, Jan 1, 1963
Schedule B Code
8504409550
Circuit Type
doubler
Grounding Provision
not included
Individual Circuit Connection Quantity
2
Load Type
resistive
Material
selenium rectifying
Phase
single
Maximum Output Current Rating
150.0 milliamperes
Mounting Configuration
four 7/32 in. mtg holes on 2-7/16 in. by 3/4 in. mtg centers
Mounting Method
bracket(s)
Operating Ambient Temp Range
+0.0 to 35.0 celsius
Output Voltage Rating
22.0 dc volts maximum
Overall Height
3.750 inches nominal
Overall Length
3.000 inches nominal
Overall Width
1.375 inches nominal
Rectification Method
half wave and full wave
Rms Input Maximum Voltage Rating
52.0 volts
Surface Treatment
high humidity,salt spray and fungus proof resistant coating
Terminal Quantity
6
Terminal Type
solder lug

Identification

Demilitarization Code
B - Usml items - mutilation to the point of scrap required worldwide. (note 7).
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Source of Supply Code
S9G - Defense supply center richmond, virginia 23297
Pseudo Item Name Code
0020974

Cross Reference

CAGE Codes

80064
Naval Ship Systems Command
U.s./canadian manufacturers
07860
Bogue Electric Manufacturing Co
U.s./canadian manufacturers
0BXF1
Bogue Systems Inc Dba Bogue Systems Inc
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35110
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
062900

Schedule B & Trade

Schedule B
8504-40-9550
Description
rectifiers and rectifying apparatus, nesoi
End Use
20000 - Generators, accessories
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77121
(NAICS) North American Industrial Classification System
334419

Questions & Answers

  1. What is the FSCG of the NSN 6130-00-028-6911?

    The FSCG of the NSN 6130-00-028-6911 is 6130

  2. Does the NSN 6130-00-028-6911 have a Schedule B code assigned?

    Yes, the Schedule B code is 8504409550

  3. Does NSN 6130-00-028-6911 require demilitarization?

    Usml items - mutilation to the point of scrap required worldwide. (note 7).

  4. Does NSN 6130-00-028-6911 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6130-00-028-6911 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 6130-00-028-6911 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.