Circuit Breaker

60.0 single location frequency in hertz, overcurrent single location circuit protection type, at pole one actuator position designation, series trip single location internal trip release configuration, trip-reset actuator function.

NSN 5925-00-665-7706 Datasheet

(NSN) National Stock Number
5925-00-665-7706
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
00-665-7706
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Tue, Jan 1, 1963
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Circuit Protection Type
overcurrent single location
Frequency In Hertz
60.0 single location
Internal Trip Release Configuration
series trip single location
Manual Actuator Type And Quantity
1 toggle
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
Mounting Facility Type And Quantity
2 slot
Pole Quantity
1
Reset Method
automatic
Terminal Type And Quantity
2 screw
Trip Release Characteristic
instantaneous and time delay single location
Trip Release Method
magnetic single location
Trip Delay Time In Seconds Per Rated Continuous Current
1.600 minimum at 125 pct and 7.000 maximum at 125 pct and 0.320 minimum at 200 pct and 0.980 maximum at 200 pct and 0.140 minimum at 300 pct and 0.400 maximum at 300 pct single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

74193
Eaton Corp Heinemann Products Commercial Controls Div
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Less than Carload Rating
P - 77.5
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-00-665-7706?

    The FSCG of the NSN 5925-00-665-7706 is 5925

  2. Does the NSN 5925-00-665-7706 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-00-665-7706 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-00-665-7706 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5925-00-665-7706 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-00-665-7706 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.