1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. CB5287

NSN CB5287

Circuit Breaker

trip-reset actuator function, at pole two actuator position designation, air arc quenching method, multipole-single actuator type body style, 10.125 inches nominal body length.

NSN 5925-00-503-7516 Datasheet

(NSN) National Stock Number
5925-00-503-7516
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
00-503-7516
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Tue, Jan 1, 1963
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Arc Quenching Method
air
Body Length
10.125 inches nominal
Body Style
multipole-single actuator type
Body Width
8.250 inches nominal
Boss Height
0.219 inches nominal
Center To Center Distance Between Terminals Parallel To Length
9.125 inches nominal
Center To Center Distance Between Terminals Parallel To Width
5.500 inches nominal
Circuit Protection Type
overcurrent all locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.250 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.750 inches nominal
Fragility Factor
moderately rugged
Frequency In Hertz
60.0 all locations
Inclosure Protection Type For Which Designed
moisture resistant
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
150.0 amperes ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations
Mounting Facility Type And Quantity
4 unthreaded hole(s)
Mounting Surface To Terminal End Distance
3.812 inches nominal
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Pole Quantity
3
Reset Method
manual
Storage Type
general purpose warehouse
Terminal Type And Quantity
6 bus bar
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Trip Release Characteristic
instantaneous and time delay all locations
Trip Release Method
thermal-magnetic all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
333.0 all locations
Unthreaded Mounting Hole Diameter
0.312 inches nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

89946
Eaton Corporation Dba Eaton Inoac
Non-manufacturers
79500
Westinghouse Electric Corp
U.s./canadian manufacturers
09017
Edo
U.s./canadian manufacturers
60969
General Electric Co Electrical Distribution and Control
U.s./canadian manufacturers
21810
Challenger Electrical Equipment Corp
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-00-503-7516?

    The FSCG of the NSN 5925-00-503-7516 is 5925

  2. Does the NSN 5925-00-503-7516 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-00-503-7516 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-00-503-7516 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5925-00-503-7516 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-00-503-7516 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.