Digital Microcircuit

0.140 inches minimum and 0.180 inches maximum body height, monolithic and hermetically sealed and positive outputs and high speed and high voltage and w/open collector features provided, 0.660 inches minimum and 0.785 inches maximum body length, 6 buffer, inverting and 6 driver, inverting and 6 inverter, digital design function and quantity, 0.220 inches minimum and 0.280 inches maximum body width.

NSN 5962-00-163-4095 Datasheet

(NSN) National Stock Number
5962-00-163-4095
(FSC) Federal Supply Classification
5962 - Electronic Microcircuits
(NIIN) National Item Identification Number
00-163-4095
Requires Demilitarization
Yes
(INC) Item Name Code
31779
Date
Wed, Nov 3, 1971
Schedule B Code
8542900000
Body Height
0.140 inches minimum and 0.180 inches maximum
Body Length
0.660 inches minimum and 0.785 inches maximum
Body Width
0.220 inches minimum and 0.280 inches maximum
Design Function And Quantity
6 buffer, inverting and 6 driver, inverting and 6 inverter, digital
Features Provided
monolithic and hermetically sealed and positive outputs and high speed and high voltage and w/open collector
Inclosure Configuration
dual-in-line
Inclosure Material
metal and silicon
Input Circuit Pattern
6 input
Maximum Power Dissipation Rating
10.0 milliwatts
Operating Temp Range
-0.0 to 85.0 celsius
Output Logic Form
transistor-transistor logic
Storage Temp Range
-65.0 to 150.0 celsius
Terminal Surface Treatment
solder
Terminal Type And Quantity
16 printed circuit
Test Data Document
00752-373429 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Time Rating Per Chacteristic
55.00 nanoseconds maximum propagation delay time, low to high level output and 15.00 nanoseconds maximum propagation delay time, high to low level output
Voltage Rating And Type Per Characteristic
5.5 volts maximum power source

Identification

Demilitarization Code
Q - "commerce control list items (ccli) - mut to the point of scrap required outside the united states. Inside the united states, mut is required when the demil integrity code (ic) is "3" and mut is not required when the demic is "6" (note 8)"
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0031779

Cross Reference

CAGE Codes

00752
L3harris Technologies, Inc. Dba Harris Corp Div Antenna Products
U.s./canadian manufacturers
33642
Syqwest Llc
U.s./canadian manufacturers
18324
Philips Semiconductors Inc
U.s./canadian manufacturers
01295
Texas Instruments Incorporated
U.s./canadian manufacturers

Freight Information

Air Commodity
HY -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
5 - Low sensitivity, category iv, aa&e, unclassified
Type of Cargo
3 - Electrostatic sensitive device (esd)
Uniform Freight Classification Item Number
34580
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061700

Schedule B & Trade

Schedule B
8542-90-0000
Description
electronic integrated circuits and microassembly parts
End Use
21320 - Semiconductors
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77689
(NAICS) North American Industrial Classification System
334413

Questions & Answers

  1. What is the FSCG of the NSN 5962-00-163-4095?

    The FSCG of the NSN 5962-00-163-4095 is 5962

  2. Does the NSN 5962-00-163-4095 have a Schedule B code assigned?

    Yes, the Schedule B code is 8542900000

  3. Does NSN 5962-00-163-4095 require demilitarization?

    "commerce control list items (ccli) - mut to the point of scrap required outside the united states. Inside the united states, mut is required when the demil integrity code (ic) is "3" and mut is not required when the demic is "6" (note 8)"

  4. Does NSN 5962-00-163-4095 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5962-00-163-4095 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 5962-00-163-4095 was assigned to the Federal Catalog?

    It was assigned 54 years ago, on Wed, Nov 3, 1971

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.