1. Home /
  2. FSC NSN Catalog /
  3. Semiconductor Devices and Associated Hardware /
  4. CD6196-2

NSN CD6196-2

Transistor

collector electrode internally-electrically connected to case, hermetically sealed case features provided, junction contact internal configuration, 30.00 amperes maximum collector current, dc and 4.00 amperes maximum base current, dc current rating per characteristic, to-3 joint electronic device engineering council/jedec/case outline designation.

NSN 5961-00-236-7939 Datasheet

(NSN) National Stock Number
5961-00-236-7939
(FSC) Federal Supply Classification
5961 - Semiconductor Devices and Associated Hardware
(NIIN) National Item Identification Number
00-236-7939
Requires Demilitarization
Yes
(INC) Item Name Code
20588
Date
Mon, Mar 15, 1971
Schedule B Code
8541500080
Current Rating Per Characteristic
30.00 amperes maximum collector current, dc and 4.00 amperes maximum base current, dc
Electrode Internally-Electrically Connected To Case
collector
Features Provided
hermetically sealed case
Internal Configuration
junction contact
Joint Electronic Device Engineering Council/Jedec/Case Outline Designation
to-3
Maximum Operating Temp Per Measurement Point
200.0 celsius junction
Mounting Facility Quantity
2
Mounting Method
unthreaded hole(s)
Overall Height
0.350 inches nominal
Overall Length
1.573 inches maximum
Overall Width
1.050 inches maximum
Power Rating Per Characteristic
120.0 watts maximum total power dissipation
Semiconductor Material
silicon
Special Features
junction pattern arrangement: npn
Terminal Type And Quantity
2 pin
Voltage Rating In Volts Per Characteristic
80.0 maximum collector to base voltage/static/emitter open and 80.0 maximum collector to emitter voltage/static/base open and 7.0 maximum emitter to base voltage, static, collector open

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0020588

Cross Reference

CAGE Codes

09150
Ampex Data Systems Corp Computer Products Div
U.s./canadian manufacturers
92739
Ampex Systems Corp
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34525
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
063025

Questions & Answers

  1. What is the FSCG of the NSN 5961-00-236-7939?

    The FSCG of the NSN 5961-00-236-7939 is 5961

  2. Does the NSN 5961-00-236-7939 have a Schedule B code assigned?

    Yes, the Schedule B code is 8541500080

  3. Does NSN 5961-00-236-7939 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5961-00-236-7939 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5961-00-236-7939 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 5961-00-236-7939 was assigned to the Federal Catalog?

    It was assigned 55 years ago, on Mon, Mar 15, 1971

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.