1. Home /
  2. FSC NSN Catalog /
  3. Electric Lamps /
  4. CF02WTS2182

NSN CF02WTS2182

Cartridge Lamp

A tubular shaped item with or without flange(s) designed to reduce friction and carry a kinetic load on the surface(s) parallel to the axis of the bore. It must have a visible or detectable means of lubrication or be self-lubricated. The over all length must exceed 25 percent of the outside diameter or the shortest distance between peripheral flats of the body, except for straight tubular (without flange or shoulder) items having a bearing surface(s) parallel to the axis of the bore only. Includes items which are divided into two or more segments which include 180 degrees (3.141 radians) or less of the bearing periphery. See also bushing, sleeve; spacer, sleeve; and washer (as modified). Excludes:pin, hollow.

50000.0 average life rating in hours, 0.330 inches nominal cartridge overall diameter, 0.968 inches maximum cartridge overall length, flush cartridge style, cartridge two pin polarized base style.

NSN 6240-00-176-5611 Datasheet

(NSN) National Stock Number
6240-00-176-5611
(FSG) Federal Supply Group
62 - Lighting Fixtures and Lamps
(FSC) Federal Supply Classification
6240 - Electric Lamps
(NIIN) National Item Identification Number
00-176-5611
Requires Demilitarization
Yes
(INC) Item Name Code
24416
Date
Fri, Nov 14, 1969
Schedule B Code
9405400000
Average Life Rating In Hours
50000.0
Base Style
cartridge two pin polarized
Cartridge Overall Diameter
0.330 inches nominal
Cartridge Overall Length
0.968 inches maximum
Cartridge Style
flush
Current Rating For Which Designed
0.080 milliamperes nominal
Lens Color
white
Lens Light Transmission Characteristic
translucent
Light Output Rating
unable to decode
Material
unable to decode
Primary Lamp Type
incandescent
Rated Average Life
hours
Voltage Rating
14.000 volts nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0024416

Cross Reference

CAGE Codes

50664
System Industries Inc
U.s./canadian manufacturers
83330
Dialight Corporation
U.s./canadian manufacturers
75915
Littelfuse, Inc.
U.s./canadian manufacturers
07294
Genisco Filter Corp
U.s./canadian manufacturers
13050
Spectrum Control, Inc. Div Api Technologies - Eis/wesson
Non-manufacturers
96682
Genisco Technology Corporation
U.s./canadian manufacturers
D9182
Zf Industrieantriebe Witten Gmbh
Non-us manufacturer (nato), other foreign organization or codification bureaus
71744
Chicago Miniature Lighting Llc Dba Chicago Miniature Optoelectron
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
55690
Water Commodity
761 - Electric lamps
National Motor Freight Classification Item Number
109700

Questions & Answers

  1. What is the FSCG of the NSN 6240-00-176-5611?

    The FSCG of the NSN 6240-00-176-5611 is 6240

  2. Does the NSN 6240-00-176-5611 have a Schedule B code assigned?

    Yes, the Schedule B code is 9405400000

  3. Does NSN 6240-00-176-5611 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6240-00-176-5611 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 6240-00-176-5611 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 6240-00-176-5611 was assigned to the Federal Catalog?

    It was assigned 56 years ago, on Fri, Nov 14, 1969

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 1 day ago
View History