1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. CQD320

NSN CQD320

Circuit Breaker

plastic case material, 20.0 amperes ac all locations maximum continuous load current rating per pole, 60.0 all locations frequency in hertz, overcurrent all locations circuit protection type, space fence end item identification.

NSN 5925-01-667-2863 Datasheet

(NSN) National Stock Number
5925-01-667-2863
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-667-2863
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Wed, Oct 11, 2017
Schedule B Code
8536200040
Circuit Protection Type
overcurrent all locations
End Item Identification
space fence
Frequency In Hertz
60.0 all locations
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
14000.0 ac all locations
Mounting Facility Type And Quantity
1 din rail
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations
Overall Height
4.90 inches nominal
Overall Width
3.00 inches nominal
Pole Quantity
3
Reset Method
manual
Terminal Type And Quantity
6 compression
Trip Release Characteristic
time delay all locations
Trip Release Method
thermal-magnetic all locations

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

66842
Siemens Energy and Automation Inc Ite Circuit Protection Div
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-667-2863?

    The FSCG of the NSN 5925-01-667-2863 is 5925

  2. Does the NSN 5925-01-667-2863 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-667-2863 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-667-2863 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-667-2863 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-667-2863 was assigned to the Federal Catalog?

    It was assigned 8 years ago, on Wed, Oct 11, 2017

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.