Circuit Breaker

A washer having a centrally located hole with a solid or laminated cross-section and two flat parallel bearing surfaces. The hole must be 75 percent or less than the largest dimension and the bearing surface finish is greater than 32 microinch (0.8 micrometer). The thickness cannot exceed 25 percent of the largest outside dimension. When the largest outside dimension is less than 1/4 inch or 6mm, the thickness must be 0.006 inches (0.15mm) or greater and for items 1/4 inch (6mm) or larger, the thickness must be 0.016 inches (0.4mm) or greater. The maximum tolerance is applied to dimensions and used as a determining factor. Items with separable lamination use shim. For items fabricated from ceramic or electrically rated materials by specification or industry standards use insulator (1), washer. Excludes:disk, valve, graphite impregnated and lubricated items.

6.000 inches nominal6.000 inches nominal body length, magnetic blowoutmagnetic blowout arc quenching method, multipole-multiple actuator typemultipole-multiple actuator type body style, trip-resettrip-reset actuator function, at pole twoat pole two actuator position designation.

NSN 5925-00-265-9488 Datasheet

(NSN) National Stock Number
5925-00-265-9488
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
00-265-9488
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Tue, Jan 1, 1963
Schedule B Code
8536200040
Actuator Function
trip-resettrip-reset
Actuator Position Designation
at pole twoat pole two
Arc Quenching Method
magnetic blowoutmagnetic blowout
Body Length
6.000 inches nominal6.000 inches nominal
Body Style
multipole-multiple actuator typemultipole-multiple actuator type
Body Width
2.750 inches nominal2.750 inches nominal
Bushing Length
0.125 inches nominal0.125 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.062 inches nominal5.062 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal1.375 inches nominal
Circuit Protection Type
overcurrent all locationsovercurrent all locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.500 inches nominal4.500 inches nominal
Fragility Factor
moderately ruggedmoderately rugged
Frequency In Hertz
60.0 all locations60.0 all locations
Inclosure Protection Type For Which Designed
dustproof and dustproof and general purpose and general purpose and fungus resistantfungus resistant
Main Contact Tripping Mechanism Type
trip freetrip free
Manual Actuator Type And Quantity
1 toggle1 toggle
Material
plastic caseplastic case
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac and 60.0 amperes ac and 60.0 amperes dc all locations60.0 amperes dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac and 10000.0 ac and 5000.0 dc all locations5000.0 dc all locations
Mounting Facility Type And Quantity
2 unthreaded hole(s)2 unthreaded hole(s)
Mounting Surface To Terminal End Distance
3.375 inches nominal3.375 inches nominal
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and 240.0 ac and 250.0 dc all locations250.0 dc all locations
Pole Quantity
22
Reset Method
manualmanual
Special Handling Feature
magneticmagnetic
Storage Type
general purpose warehousegeneral purpose warehouse
Terminal Type And Quantity
4 compression4 compression
Trip Release Ambient Temp Rating
50.0 celsius nominal all locations50.0 celsius nominal all locations
Trip Release Characteristic
time delay all locationstime delay all locations
Trip Release Method
thermal-magnetic all locationsthermal-magnetic all locations
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct and 20.000 minimum at 200 pct and 105.000 maximum at 200 pct all locations105.000 maximum at 200 pct all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations125.0 all locations
Unpackaged Unit Weight
3.000 pounds nominal3.000 pounds nominal
Unthreaded Mounting Hole Diameter
0.188 inches nominal0.188 inches nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

65054
Westinghouse Electric Corp Power Generation-Generator Div
U.s./canadian manufacturers
79500
Westinghouse Electric Corp
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-00-265-9488?

    The FSCG of the NSN 5925-00-265-9488 is 5925

  2. Does the NSN 5925-00-265-9488 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-00-265-9488 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-00-265-9488 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-00-265-9488 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-00-265-9488 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.