NSN FAF805

Low Pass Filter

A grouping of two or more physically connected or related electrical an/or electronic parts capable of dissassemblage. Each component of the assemblage must be capable of functioning in accordance with its own item name. Consists of a single printed circuit board or terminal board upon which are mounted separately manufactured electronic components such as capacitors, inductors, resistors, and the like. It may also include printed electronic components. The item is generally part of a subassembly and cannot be assigned a more definite item name. For items having a complete individual electrical/electronic function, use applicable item name such as amplifier (as modified); power supply; or the like. For items not having a complete individual electrical/electronic function, see applicable subassembly name, such as amplifier subassembly; power supply subassembly; or the like. For an assembly of electrical/electronic components mounted on other than a single printed wiring board, see electronic components assembly. Excludes:printed circuit board

2.270 inches maximum body length, 0.808 inches maximum body height, 1.00 kilohertz blank and 15.00 kilohertz blank frequency band width per function, 1.250 inches nominal distance between centerlines of mounting facilities parallel to body length, 100.0 minimum blank and 94.0 minimum blank and 88.0 minimum blank discrimination at specified frequencies per function in decibels.

NSN 5915-01-030-9796 Datasheet

(NSN) National Stock Number
5915-01-030-9796
(FSC) Federal Supply Classification
5915 - Filters and Networks
(NIIN) National Item Identification Number
01-030-9796
Requires Demilitarization
Yes
(INC) Item Name Code
13911
Date
Tue, Nov 16, 1976
Schedule B Code
8527995030
Body Height
0.808 inches maximum
Body Length
2.270 inches maximum
Discrimination At Specified Frequencies Per Function In Decibels
100.0 minimum blank and 94.0 minimum blank and 88.0 minimum blank
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.250 inches nominal
Frequency Band Width Per Function
1.00 kilohertz blank and 15.00 kilohertz blank
Functional Terminal Type And Quantity
4 pin input-output/ground
Inclosure Type
hermetically sealed
Insertion Loss At Reference Frequency Per Function In Decibels
1.0 blank
Load Impedance Per Function
3.0 kilohms blank
Mounting Facility Screw Thread Series Designator
unified national coarse (unc)
Mounting Facility Type And Quantity
2 threaded stud(s)
Nominal Thread Size
0.112 inches
Overall Height
1.058 inches maximum
Overall Length
2.450 inches maximum
Overall Width
0.520 inches maximum
Reference Frequency Per Function
1.0 kilohertz blank
Source Impedance Rating Per Function
3.0 kilohms blank
Specified Frequencies Of Discrimination Per Function
125.00 kilohertz blank and 250.00 kilohertz blank and 375.00 kilohertz blank

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0013911

Cross Reference

CAGE Codes

06978
Vernitron Corp Aie Magnetics Div
U.s./canadian manufacturers
00222
Esc Control Electronics Llc Dba Control Electronics Division of Fil-Coil
U.s./canadian manufacturers
00144
Te Connectivity Networks, Inc. Div Adc Telecommunications Sales, Inc.
U.s./canadian manufacturers
13499
Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
U.s./canadian manufacturers
15634
Magnetika Inc
U.s./canadian manufacturers
80223
United Transformer Corp Sub of Opt Industries Inc
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Less than Carload Rating
P - 77.5
National Motor Freight Class Rating
P - 77.5
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34450
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061400

Schedule B & Trade

Schedule B
8527-99-5030
Description
reception apparatus, nesoi
End Use
41210 - Stereo equipment, etc.
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
76289
(NAICS) North American Industrial Classification System
334310

Questions & Answers

  1. What is the FSCG of the NSN 5915-01-030-9796?

    The FSCG of the NSN 5915-01-030-9796 is 5915

  2. Does the NSN 5915-01-030-9796 have a Schedule B code assigned?

    Yes, the Schedule B code is 8527995030

  3. Does NSN 5915-01-030-9796 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5915-01-030-9796 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5915-01-030-9796 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5915-01-030-9796 was assigned to the Federal Catalog?

    It was assigned 49 years ago, on Tue, Nov 16, 1976

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.