1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. FD3035V

NSN FD3035V

Circuit Breaker

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

magnetic blowout arc quenching method, trip-reset actuator function, 3.375 inches nominal body height, 6.000 inches nominal body length, at pole two actuator position designation.

NSN 5925-00-174-6328 Datasheet

(NSN) National Stock Number
5925-00-174-6328
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
00-174-6328
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Sun, Jan 1, 1961
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Arc Quenching Method
magnetic blowout
Body Height
3.375 inches nominal
Body Length
6.000 inches nominal
Body Style
multipole-single actuator type
Body Width
4.125 inches nominal
Boss Height
0.125 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.062 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
Circuit Protection Type
overcurrent all locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.500 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
Fragility Factor
moderately rugged
Frequency In Hertz
60.0 all locations
Inclosure Protection Type For Which Designed
general purpose
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations
Mounting Facility Type And Quantity
4 unthreaded hole(s)
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Pole Quantity
3
Reset Method
manual
Special Handling Feature
magnetic
Storage Type
general purpose warehouse
Terminal Type And Quantity
6 compression
Trip Delay Time In Seconds Per Rated Continuous Current
50.000 minimum at 200 pct and 220.000 maximum at 200 pct all locations
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Trip Release Characteristic
instantaneous and time delay all locations
Trip Release Method
thermal-magnetic all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Unthreaded Mounting Hole Diameter
0.187 inches nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

79500
Westinghouse Electric Corp
U.s./canadian manufacturers
60969
General Electric Co Electrical Distribution and Control
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Less than Carload Rating
P - 77.5
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-00-174-6328?

    The FSCG of the NSN 5925-00-174-6328 is 5925

  2. Does the NSN 5925-00-174-6328 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-00-174-6328 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-00-174-6328 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5925-00-174-6328 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-00-174-6328 was assigned to the Federal Catalog?

    It was assigned 65 years ago, on Sun, Jan 1, 1961

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.