1. Home /
  2. FSC NSN Catalog /
  3. Supplies, Equipment and Medical and Surgical Instruments /
  4. FMS 2000

NSN FMS 2000

Fluid Warming and Iinfusion Syst

A resilient metal item, circular or nearly circular, which is designed to be inserted into an internal or external groove and retained by its own spring action, or it may have external prongs or projections designed to be inserted into a hole and retained by spring action of the prongs which grip by imbedding into the material. For items having internal prongs which perform the same function, see push on nut. It is used to keep and/or lock a part(s) in position, as a ball bearing on a shaft or in a housing. See also clip, retaining and pin, lock. Excludes:ring, connecting, round.

13.5x7.5 x12.0 in., quick on iv pole mount or handle at top of unit; internal battery operates all functions w/o heating, rechargeable for transport; roller type peristaltic pump fluid pump; maximum applied power heater, 1350 watts; 2 air bubble sensors, 2 temp probes (nfared sensing), pump flow rate sensor; built-in control computer controls all functions with redundant hardwired overrides in case of computer failure; 5 x 2.5 in. display, electroluminescent type with waterproof touch pad supplementary features, fms 2000 rapid infuser, field version. part name assigned by controlling agency, small; lightweight; fluid management system; self-contained; c/o: warmer, volumetric fluid pump and safety devices; designed for transport with a built-in battery; can be used for procedures with blood loss of hypothermia; capable of infusion rates up to 500 ml/min. special features.

NSN 6515-01-465-2059 Datasheet

(NSN) National Stock Number
6515-01-465-2059
(NIIN) National Item Identification Number
01-465-2059
Requires Demilitarization
Yes
(INC) Item Name Code
77777
Date
Wed, May 26, 1999
Part Name Assigned By Controlling Agency
fms 2000 rapid infuser, field version.
Special Features
small; lightweight; fluid management system; self-contained; c/o: warmer, volumetric fluid pump and safety devices; designed for transport with a built-in battery; can be used for procedures with blood loss of hypothermia; capable of infusion rates up to 500 ml/min.
Supplementary Features
13.5x7.5 x12.0 in., quick on iv pole mount or handle at top of unit; internal battery operates all functions w/o heating, rechargeable for transport; roller type peristaltic pump fluid pump; maximum applied power heater, 1350 watts; 2 air bubble sensors, 2 temp probes (nfared sensing), pump flow rate sensor; built-in control computer controls all functions with redundant hardwired overrides in case of computer failure; 5 x 2.5 in. display, electroluminescent type with waterproof touch pad

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Pseudo Item Name Code
1919458

Cross Reference

CAGE Codes

89875
Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia
U.s./canadian manufacturers
64616
Defense Medical Standardization Board
U.s./canadian manufacturers
9009H
Jednolity Indeks Materialowy - Uniform Material Index
Government departments or units, including military organizations
5Z133
Belmont Instrument Llc
U.s./canadian manufacturers
Z3935
Getz Healthcare Pty Ltd
Non-us manufacturer (nato), other foreign organization or codification bureaus
Z0542
Configuration Management Centre Specifications and Standards Department of Defence
Military standards and standards organizations (ex:stanags,milspecs,defstans)

Freight Information

Air Commodity
MZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
00000
Water Commodity
651 - Instruments, medical and surgical
National Motor Freight Classification Item Number
056590

Questions & Answers

  1. What is the FSCG of the NSN 6515-01-465-2059?

    The FSCG of the NSN 6515-01-465-2059 is 6515

  2. Does NSN 6515-01-465-2059 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  3. Does NSN 6515-01-465-2059 contain precious materials?

    Item does not contain precious metal.

  4. Does NSN 6515-01-465-2059 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  5. When the NSN 6515-01-465-2059 was assigned to the Federal Catalog?

    It was assigned 27 years ago, on Wed, May 26, 1999

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.