1. Home /
  2. FSC NSN Catalog /
  3. Capacitors /
  4. FT20

NSN FT20

Ceramic Dielectr Fixed Capacitor

200.000 picofarads single section capacitance value per section, w/thd mtg bushing, terminals on opposite ends body style, 0.625 inches nominal body length, 1 threaded bushing mounting facility type and quantity, unf mounting facility screw thread series designator.

NSN 5910-00-660-8010 Datasheet

(NSN) National Stock Number
5910-00-660-8010
(FSC) Federal Supply Classification
5910 - Capacitors
(NIIN) National Item Identification Number
00-660-8010
Requires Demilitarization
Yes
(INC) Item Name Code
00007
Date
Tue, Jan 1, 1963
Schedule B Code
8532290040
Body Length
0.625 inches nominal
Body Style
w/thd mtg bushing, terminals on opposite ends
Capacitance Value Per Section
200.000 picofarads single section
Mounting Facility Screw Thread Series Designator
unf
Mounting Facility Type And Quantity
1 threaded bushing
Nominal Thread Size
0.216 inches
Nonderated Operating Temp
-55.0 celsius minimum and 85.0 celsius maximum
Nonderated Continuous Voltage Rating And Type Per Section
500.0 dc single section
Reliability Indicator
not established
Schematic Diagram Designator
feedthrough
Terminal Diameter
0.051 inches nominal
Terminal Length
0.265 inches nominal
Terminal Type And Quantity
2 uninsulated wire lead
Tolerance Range Per Section
-20.00 to 20.00 percent single section
Width Across Flats
0.312 inches nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0000007

Cross Reference

CAGE Codes

10402
Whelen Engineering Company, Inc. Dba Whelen Engineering Co Inc Div Whelen Engineering Company
U.s./canadian manufacturers
18338
Xerox Corp Xerox Documentation and Software Services
U.s./canadian manufacturers
71590
Crl Components Inc
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
P - 77.5
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34450
Water Commodity
723 - Radio parts and equipment, excluding tubes packed separately
National Motor Freight Classification Item Number
061400

Schedule B & Trade

Schedule B
8532-29-0040
Description
fixed capacitors, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77867
(NAICS) North American Industrial Classification System
334416

Questions & Answers

  1. What is the FSCG of the NSN 5910-00-660-8010?

    The FSCG of the NSN 5910-00-660-8010 is 5910

  2. Does the NSN 5910-00-660-8010 have a Schedule B code assigned?

    Yes, the Schedule B code is 8532290040

  3. Does NSN 5910-00-660-8010 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5910-00-660-8010 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5910-00-660-8010 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5910-00-660-8010 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent