Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Circuit Breaker

Model / MPN: IUGN666-1REC4-20545-1 | NSN: 5925-01-368-3723
ITAR Registered seal

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

Product Details
NATO Stock Number
5925-01-368-3723
Sold in multiples of
1 EA
DEMIL
NO
Bushing Length
0.625 inches
Body Length
2.000 inches
Body Width
2.625 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
1.530 inches
Center To Center Distance Between Terminals Parallel To Width
0.750 inches
Switch Contact Arrangement
Single pole, double throw
Mounting Surface To Terminal End Distance
2.232 inches
Pole Quantity
3
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.500 inches
Switch Location And Position Designation
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
2.200 at 200 pct all locations and 25.000 at 200 pct all locations
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
10.0 ac and 1.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Frequency In Hertz
60.0 all locations
Thread Series Designator
Un
Terminal Type And Quantity
6 tab w/screw
Solicitations
Solicitation Description Qty UOM Close Date
SPE7M515T6867 Circuit Breaker 5 EA 05/11/2015
SPE7M516T0547 Circuit Breaker 16 EA 10/19/2015
SPE7M517T1733 Circuit Breaker 14 EA 12/30/2016
SPE7M517T3865 Circuit Breaker 14 EA 02/04/2017

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
IUGN666-1REC4-20545-1 Cross Reference
  • 1207056
  • 5946263
  • APGN 666-1REC4-20545-1