  4. KD1-8A

NSN KD1-8A

Circuit Breaker

single pole typesingle pole type body style, 2.150 inches nominal2.150 inches nominal body length, at pole one actuator position designation, trip-reset actuator function, airair arc quenching method.

NSN 5925-01-247-9388 Datasheet

(NSN) National Stock Number
5925-01-247-9388
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-247-9388
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Thu, Jan 15, 1987
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Arc Quenching Method
airair
Body Length
2.150 inches nominal2.150 inches nominal
Body Style
single pole typesingle pole type
Circuit Protection Type
overcurrent single location
Cubic Measure
0.949 cubic inches0.949 cubic inches
Fragility Factor
moderately ruggedmoderately rugged
Frequency In Hertz
50.0 or 60.0 single location
Internal Trip Release Configuration
series trip single location
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push button
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
8.0 amperes ac and 8.0 amperes dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 200.0 dc single location
Mounting Facility Type And Quantity
1 terminal1 terminal
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and 32.0 dc single location
Overall Diameter
0.750 inches nominal0.750 inches nominal
Pole Quantity
11
Reset Method
manual
Storage Type
general purpose warehousegeneral purpose warehouse
Terminal Type And Quantity
2 quick disconnect, male
Trip Release Characteristic
time delay single location
Trip Release Method
magnetic single location
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 10.000 maximum at 200 pct single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

74193
Eaton Corp Heinemann Products Commercial Controls Div
U.s./canadian manufacturers

Freight Information

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-247-9388?

    The FSCG of the NSN 5925-01-247-9388 is 5925

  2. Does the NSN 5925-01-247-9388 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-247-9388 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-247-9388 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-247-9388 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-247-9388 was assigned to the Federal Catalog?

    It was assigned 39 years ago, on Thu, Jan 15, 1987

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.