1. Home /
  2. FSC NSN Catalog /
  3. Fuses, Arrestors, Absorbers and Protectors /
  4. KSA6DBF

NSN KSA6DBF

Overvoltage Absorber

60.0 frequency in hertz, 3.0 current rating in amps, ac current type, 12.000 milliamperes nominal absorber current rating, not provided hermetic protection.

NSN 5920-00-989-0874 Datasheet

(NSN) National Stock Number
5920-00-989-0874
(FSC) Federal Supply Classification
5920 - Fuses, Arrestors, Absorbers and Protectors
(NIIN) National Item Identification Number
00-989-0874
Requires Demilitarization
Yes
(INC) Item Name Code
21899
Date
Mon, Jan 1, 1962
Schedule B Code
8536908010
Absorber Current Rating
12.000 milliamperes nominal
Current Rating In Amps
3.0
Current Type
ac
Frequency In Hertz
60.0
Hermetic Protection
not provided
Material
selenium element
Mounting Configuration
one no. 8-32 thd stud axiallly located
Mounting Method
threaded stud
Overall Height
1.375 inches nominal
Overall Length
1.750 inches nominal
Overall Width
1.000 inches nominal
Polarization Feature
not included
Shunt Capacitor
not included
Terminal Quantity
2
Terminal Type
lug
Voltage In Volts
150.0

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0021899

Cross Reference

CAGE Codes

79343
Asrc Federal Facilities Logistics, Llc
Non-manufacturers
93568
Harsco Corp Bmy-Combat Systems Div
U.s./canadian manufacturers
51589
St-Semicon Inc
U.s./canadian manufacturers
05869
Raytheon Company Div Rmd Strategic
U.s./canadian manufacturers
84411
American Shizuki Corp
U.s./canadian manufacturers
03508
General Electric Co Semi-Conductor Products Dept
U.s./canadian manufacturers
09214
General Electric Co Semi-Conductor Products Dept Power Components Opn
U.s./canadian manufacturers
24446
General Electric Company
U.s./canadian manufacturers
81483
Infineon Technologies Americas Corp
U.s./canadian manufacturers
05300
Rectico, Inc.
U.s./canadian manufacturers
59656
Dean Technology Inc. Dba Cke
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35120
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
062920

Schedule B & Trade

Schedule B
8536-90-8010
Description
electrical distribution ducts, for a voltage not exceeding 1,000 v
End Use
20005 - Electric apparatus
Unit of Quantity
KG
USDA
Yes
(SITC) Standard International Trade Classification
77259
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5920-00-989-0874?

    The FSCG of the NSN 5920-00-989-0874 is 5920

  2. Does the NSN 5920-00-989-0874 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536908010

  3. Does NSN 5920-00-989-0874 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5920-00-989-0874 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5920-00-989-0874 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5920-00-989-0874 was assigned to the Federal Catalog?

    It was assigned 64 years ago, on Mon, Jan 1, 1962

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.