1. Home /
  2. FSC NSN Catalog /
  3. Electrical and Electronic Properties Measuring and Testing Instruments /
  4. KX-261

NSN KX-261

Special Scale Meter

A circuit designed to store information and/or coded instructions. Item has pins or other connections to install in a computer or computing device. Does not include magnetic drums, tapes, punched cards or the like. For items that have portable type connections see memory, portable, solid state.

2 threaded stud circuit attachment method and quantity, 3.375 inches nominal center to center distance between mounting facilities parallel to width, 3.375 inches nominal center to center distance between mounting facilities parallel to length, white single indicator single range background color, unable to decode accuracy in percent.

NSN 6625-01-251-5176 Datasheet

(NSN) National Stock Number
6625-01-251-5176
(NIIN) National Item Identification Number
01-251-5176
Requires Demilitarization
Yes
(INC) Item Name Code
61955
Date
Thu, Mar 19, 1987
Schedule B Code
9030908030
Accuracy In Percent
unable to decode
Background Color
white single indicator single range
Center To Center Distance Between Mounting Facilities Parallel To Width
3.375 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
3.375 inches nominal
Circuit Attachment Method And Quantity
2 threaded stud
Circuit Current For Which Designed
dc
Dial Scale Marking Color
unable to decode
Dielectric Withstanding Voltage In Volts
800.0
Environmental Protection
shock resistant and vibration resistant
Features Provided
zero adjuster
Fsc Application Data
test set,elect. equip.
Furnished Items And Quantity
mtg hdw 4; term. hdw 2
Indicator Type
dial w/pointer
Installation Design
panel
Meter Body Diameter Behind Mounting Flange
3.960 inches nominal
Meter Depth Behind Mounting Flange
3.656 inches nominal
Mounting Arrangement Style
four hole/stud rectangular/square
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole(s)
Mounting Hole Diameter
0.313 inches nominal
Movement Suspension Method
taut band
Movement Type
moving coil, permanent magnet
Nuclear Hardness Critical Feature
nonhardened
Overall Height
8.750 inches nominal
Overall Length
5.609 inches nominal
Overall Width
8.750 inches nominal
Panel For Which Designed
nonmagnetic
Pointer Color
unable to decode
Scale Marking
deg f; 400; 500; 600; 700; 800; 900; 1000; 1100; 1200
Scale Division Quantity
unable to decode
Scale Graduation Type
unable to decode
Sensitivity Rating
20.0 milliamperes
Special Markings
off at 0 deflection
Special Test Features
complies w/ansi standards c39.1
Style Designator
rectangular flush mtg

Identification

Demilitarization Code
Q - "commerce control list items (ccli) - mut to the point of scrap required outside the united states. Inside the united states, mut is required when the demil integrity code (ic) is "3" and mut is not required when the demic is "6" (note 8)"
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0061955

Cross Reference

CAGE Codes

55281
Nationwide Electronic Systems Inc System Components Div
U.s./canadian manufacturers
88416
Hughes Corp
U.s./canadian manufacturers
6Z382
Hughes Corp Div Weschler Electric
U.s./canadian manufacturers

Freight Information

Air Commodity
VZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34580
Water Commodity
653 - Musical instruments
National Motor Freight Classification Item Number
061700

Schedule B & Trade

Schedule B
9030-90-8030
Description
parts and accessories of articles of schedule b subheading 9030.39
End Use
21160 - Measuring, testing, control instruments
Unit of Quantity
KG
USDA
Yes
(SITC) Standard International Trade Classification
87479
(NAICS) North American Industrial Classification System
334515

Questions & Answers

  1. What is the FSCG of the NSN 6625-01-251-5176?

    The FSCG of the NSN 6625-01-251-5176 is 6625

  2. Does the NSN 6625-01-251-5176 have a Schedule B code assigned?

    Yes, the Schedule B code is 9030908030

  3. Does NSN 6625-01-251-5176 require demilitarization?

    "commerce control list items (ccli) - mut to the point of scrap required outside the united states. Inside the united states, mut is required when the demil integrity code (ic) is "3" and mut is not required when the demic is "6" (note 8)"

  4. Does NSN 6625-01-251-5176 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6625-01-251-5176 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 6625-01-251-5176 was assigned to the Federal Catalog?

    It was assigned 39 years ago, on Thu, Mar 19, 1987

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 1 day ago
View History