Pressure Switch

unable to decode contact load current rating, 1.500 inches nominal body length, 5.50 actuation point nominal pounds per square inch and 6.50 deactuation point nominal pounds per square inch and 1.00 differential point nominal pounds per square inch contact stimulus rating, deactuation point not adjustable and actuation point not adjustable contact adjustability, decrease contact action stimulus.

NSN 5930-00-272-1361 Datasheet

(NSN) National Stock Number
5930-00-272-1361
(FSC) Federal Supply Classification
5930 - Switches
(NIIN) National Item Identification Number
00-272-1361
Requires Demilitarization
Yes
(INC) Item Name Code
00206
Date
Tue, Jan 1, 1963
Schedule B Code
8536509065
Body Length
1.500 inches nominal
Contact Action Stimulus
decrease
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
Contact Load Current Rating
unable to decode
Contact Stimulus Rating
5.50 actuation point nominal pounds per square inch and 6.50 deactuation point nominal pounds per square inch and 1.00 differential point nominal pounds per square inch
Contact Voltage Rating In Volts
unable to decode
Features Provided
pilot light
Media For Which Designed
gas or liquid
Mounting Method
inlet connection
Nominal Thread Size
unable to decode
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
Outside Diameter
unable to decode
Overall Diameter
1.690 inches nominal
Overall Length
2.000 inches nominal
Pressure Connector Type
unable to decode
Pressure Switch Type
gage
Proof Pressure
150.00 pounds per square inch
Special Features
mounts by means of 1/8-27 male pipe thd formed on neck
Style Designator
cylindrical
Terminal Type
tab w/screw
Thread Quantity Per Inch
unable to decode
Thread Series Designator
unable to decode

Identification

Demilitarization Code
Q - "commerce control list items (ccli) - mut to the point of scrap required outside the united states. Inside the united states, mut is required when the demil integrity code (ic) is "3" and mut is not required when the demic is "6" (note 8)"
Precious Metals Indicator
S - Item contains silver.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000206

Cross Reference

CAGE Codes

44940
Cummins Power Generation Inc.
U.s./canadian manufacturers
74400
Hobbs Corp
U.s./canadian manufacturers
19204
Army, United States Department of the Dba Rock Island Arsenal Jmtc
Non-manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-50-9065
Description
switches, for a voltage not exceeding 1000 volts, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77255
(NAICS) North American Industrial Classification System
335931

Questions & Answers

  1. What is the FSCG of the NSN 5930-00-272-1361?

    The FSCG of the NSN 5930-00-272-1361 is 5930

  2. Does the NSN 5930-00-272-1361 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536509065

  3. Does NSN 5930-00-272-1361 require demilitarization?

    "commerce control list items (ccli) - mut to the point of scrap required outside the united states. Inside the united states, mut is required when the demil integrity code (ic) is "3" and mut is not required when the demic is "6" (note 8)"

  4. Does NSN 5930-00-272-1361 contain precious materials?

    Item contains silver.

  5. Does NSN 5930-00-272-1361 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5930-00-272-1361 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 1 day ago
View History