NSN MARS MICROWAVE TISSUE PROCESSOR

Labor Automatic Tissue Processor

A collection of various o-rings, seals, sleeves, wear rings and gaskets to repair actuating cylinders. May include cylinder and mounting hardware.

20.000 inches nominal overall width, 208-230v, 50/60hz power supply; 120lbs; comes with a 180 cassette rack, 3 processing modules (1 reagents, 1 vacuum, 1 paraffin), 3 tray carriers/positioning plates, multi-function lid; integrated windows touch screen control module; integrated vacuum system; multifuctional tissue processor, which also carries out pre-stored procedures for high temp procedures, decalcification, fixation and gross hardening; provides rapid processing: 180 biopsy cassettes in 30 min and 180 standard cassettes in 90-120 min; different specimen types can be process simultaneously, no xylene is required, one-step dehydration/clearing, and re-use of paraffix wax special features, 23.000 inches nominal overall height, tissue processor microwave mars part name assigned by controlling agency, 25.000 inches nominal overall length.

NSN 6640-01-540-3044 Datasheet

(NSN) National Stock Number
6640-01-540-3044
(FSC) Federal Supply Classification
6640 - Laboratory Equipment and Supplies
(NIIN) National Item Identification Number
01-540-3044
Requires Demilitarization
Yes
(INC) Item Name Code
13627
Date
Mon, May 15, 2006
Part Name Assigned By Controlling Agency
tissue processor microwave mars
Overall Height
23.000 inches nominal
Overall Length
25.000 inches nominal
Overall Width
20.000 inches nominal
Special Features
208-230v, 50/60hz power supply; 120lbs; comes with a 180 cassette rack, 3 processing modules (1 reagents, 1 vacuum, 1 paraffin), 3 tray carriers/positioning plates, multi-function lid; integrated windows touch screen control module; integrated vacuum system; multifuctional tissue processor, which also carries out pre-stored procedures for high temp procedures, decalcification, fixation and gross hardening; provides rapid processing: 180 biopsy cassettes in 30 min and 180 standard cassettes in 90-120 min; different specimen types can be process simultaneously, no xylene is required, one-step dehydration/clearing, and re-use of paraffix wax

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0013627

Cross Reference

CAGE Codes

89875
Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia
U.s./canadian manufacturers
00571
Hacker Industries Inc Dba Hacker Instruments & Industries
U.s./canadian manufacturers

Freight Information

Air Commodity
MZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
F - 150.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
06350
Water Commodity
534 - Medical supplies (room temperature) (not requiring temperature control)
National Motor Freight Classification Item Number
014500

Questions & Answers

  1. What is the FSCG of the NSN 6640-01-540-3044?

    The FSCG of the NSN 6640-01-540-3044 is 6640

  2. Does NSN 6640-01-540-3044 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  3. Does NSN 6640-01-540-3044 contain precious materials?

    Item does not contain precious metal.

  4. Does NSN 6640-01-540-3044 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  5. When the NSN 6640-01-540-3044 was assigned to the Federal Catalog?

    It was assigned 20 years ago, on Mon, May 15, 2006

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.