NATO Stock Number
5945-01-129-4492
Sold in multiples of
1 EA
DEMIL
DEMIL/MLI
Thread Class
2a single mounting facility
Thread Direction
Right-hand single mounting facility
Thread Length
0.345 inches single mounting facility
Overall Length
1.025 inches
Center To Center Distance Between Mounting Facilities Parallel To Length
0.640 inches single mounting facility
Center To Center Distance Between Mounting Facilities Parallel To Width
0.625 inches single mounting facility
Overall Height
2.325 inches
Overall Width
1.025 inches
Case Material
Metal
Environmental Protection
Hermetic
Fragility Factor
Moderately rugged
Winding Quantity
1
Purpose For Which Designed
Specific
Coil Quantity
1
Winding Dc Resistance Rating
220.0 ohms single winding
Duty Type
Continuous
Arc Quenching Method
Air
Mounting Facility Type And Quantity
4 threaded stud single mounting facility
Storage Type
General purpose warehouse
Cubic Measure
2.443 cubic inches
Thready Qty Per Inch (tpi)
32 single mounting facility
Thread Size
0.138 inches single mounting facility
Mounting Facility Pattern
Rectangular single mounting facility
Nonpile-up Main Contact Arrangement
4 pole, double throw, one position momentary
Operating Current Rating And Type
200.0 milliamperes dc single winding
Time Delay
0.01 seconds fixed release time
Time Delay
0.015 seconds fixed operate time
Operating Voltage Rating And Type At Specificationified Temp
28.0 volts dc 25 degrees celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator
Unc single mounting facility
Terminal Type And Quantity
14 wire lead all functions
Specification Data
96906-ms27709 government standard