Circuit Breaker

overcurrent single location circuit protection type, plastic case material, trip-reset actuator function, 1 toggle manual actuator type and quantity, trip free main contact tripping mechanism type.

NSN 5925-00-175-2664 Datasheet

(NSN) National Stock Number
5925-00-175-2664
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
00-175-2664
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Sun, Jan 1, 1961
Schedule B Code
8536200040
Actuator Function
trip-reset
Circuit Protection Type
overcurrent single location
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac and 35.0 amperes dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
4000.0 ac and 4000.0 dc single location
Mounting Facility Type And Quantity
2 threaded hole(s)
Nominal Thread Size
0.164 inches
Operating Voltage Type And Rating Per Pole In Volts
24.0 ac and 24.0 dc single location
Overall Height
3.219 inches nominal
Overall Length
3.000 inches nominal
Overall Width
1.000 inches nominal
Pole Quantity
1
Reset Method
manual
Terminal Type And Quantity
2 threaded stud
Thread Quantity Per Inch
32
Thread Series Designator
unified national coarse (unc)
Trip Delay Time In Seconds Per Rated Continuous Current
300.000 nominal at 125 pct and 10.000 minimum at 200 pct and 100.000 maximum at 200 pct and 2.000 minimum at 300 pct and 22.000 maximum at 300 pct single location
Trip Release Ambient Temp Rating
50.0 celsius nominal single location
Trip Release Characteristic
time delay single location
Trip Release Method
thermal single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
100.0 single location

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

81349
Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
Military standards and standards organizations (ex:stanags,milspecs,defstans)

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Less than Carload Rating
P - 77.5
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-00-175-2664?

    The FSCG of the NSN 5925-00-175-2664 is 5925

  2. Does the NSN 5925-00-175-2664 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-00-175-2664 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-00-175-2664 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5925-00-175-2664 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-00-175-2664 was assigned to the Federal Catalog?