1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. QOB3100

NSN QOB3100

Circuit Breaker

100.0 amperes ac all locations maximum continuous load current rating per pole, 3 pole quantity, manual reset method, 50.0 all locations frequency in hertz, 240.0 ac all locations operating voltage type and rating per pole in volts.

NSN 5925-01-533-7008 Datasheet

(NSN) National Stock Number
5925-01-533-7008
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-533-7008
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Fri, Sep 23, 2005
Schedule B Code
8536200040
Frequency In Hertz
50.0 all locations
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Pole Quantity
3
Reset Method
manual
Trip Release Method
thermal-magnetic all locations

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

80063
Us Army Communications & Electronics Materiel Readiness Command Logistics Engineering Dir
U.s./canadian manufacturers
0D2L7
Drs Environmental Systems, Inc. Dba Drs Technologies
U.s./canadian manufacturers
56303
Schneider Electric Usa, Inc.
U.s./canadian manufacturers
56365
Schneider Electric Usa, Inc.
U.s./canadian manufacturers
5RQL2
Drs Environmental Systems Inc
U.s./canadian manufacturers
63637
Schneider Electric Usa, Inc. Dba Schneider Electric
U.s./canadian manufacturers
92878
Hdt Expeditionary Systems Inc
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-533-7008?

    The FSCG of the NSN 5925-01-533-7008 is 5925

  2. Does the NSN 5925-01-533-7008 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-533-7008 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-533-7008 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-533-7008 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-533-7008 was assigned to the Federal Catalog?

    It was assigned 21 years ago, on Fri, Sep 23, 2005