1. Home /
  2. FSC NSN Catalog /
  3. Resistor /
  4. RT22C2X502

NSN RT22C2X502

Resistor,variable,wire Wound,non

An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes:filter (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see transformer, radio frequency. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see suppressor, parasitic.

85.0 single section ambient temp in deg celsius per section at full rated power, 150.0 single section ambient temp in deg celsius per section at zero percent rated power, continuous motion actuator travel control feature, 0.490 inches minimum and 0.510 inches maximum body height, single shaft actuator type.

NSN 5905-00-922-4853 Datasheet

(NSN) National Stock Number
5905-00-922-4853
(FSC) Federal Supply Classification
5905 - Resistor
(NIIN) National Item Identification Number
00-922-4853
Requires Demilitarization
Yes
(INC) Item Name Code
37406
Date
Fri, Apr 26, 1968
Schedule B Code
8533390080
Actuator Travel Control Feature
continuous motion
Actuator Type
single shaft
Ambient Temp In Deg Celsius Per Section At Full Rated Power
85.0 single section
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
150.0 single section
Body Height
0.490 inches minimum and 0.510 inches maximum
Body Length
0.540 inches nominal
Body Width
0.180 inches minimum and 0.230 inches maximum
Body Style
rectangular w/mounting holes
Center To Center Distance Between Center Terminal And Outside Terminal
0.090 inches minimum and 0.110 inches maximum
Center To Center Distance Between Terminals
0.090 inches minimum and 0.110 inches maximum
Electrical Resistance Per Section
5.000 kilohms single section
Lateral Distance Between Mounting Hole Centers
0.419 inches nominal
Maximum Running Torque
5.00 inch-ounces
Mounting Method
terminal
Overall Height
0.490 inches minimum and 0.510 inches maximum
Overall Length
0.712 inches nominal
Overall Width
0.180 inches minimum and 0.230 inches maximum
Power Dissipation Rating Per Section In Watts
0.75 free air single section
Reliability Indicator
not established
Resistance Tolerance Per Section In Percent
-5.0 to 5.0 single section
Rotary Actuator Travel In Angular Deg
7200.0 minimum and 16200.0 maximum
Section Quantity
1
Shaft Diameter
0.058 inches minimum and 0.098 inches maximum
Shaft Style
round, slotted
Shaft Length
0.045 inches maximum
Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
-50.0 to 50.0 single section
Terminal Location
lower adjacent side single row
Terminal Length
0.172 inches minimum
Terminal Type And Quantity
3 pin
Test Data Document
"81349-mil-r-27208-4 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0037406

Cross Reference

CAGE Codes

81413
Bae Systems Information and Electronic Systems Integration Inc. Dba Bae Systems
U.s./canadian manufacturers
81349
Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
Military standards and standards organizations (ex:stanags,milspecs,defstans)

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
P - 77.5
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35140
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
062960

Schedule B & Trade

Schedule B
8533-39-0080
Description
wirewound variable resistors, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77233
(NAICS) North American Industrial Classification System
334416

Questions & Answers

  1. What is the FSCG of the NSN 5905-00-922-4853?

    The FSCG of the NSN 5905-00-922-4853 is 5905

  2. Does the NSN 5905-00-922-4853 have a Schedule B code assigned?

    Yes, the Schedule B code is 8533390080

  3. Does NSN 5905-00-922-4853 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5905-00-922-4853 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5905-00-922-4853 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 5905-00-922-4853 was assigned to the Federal Catalog?

    It was assigned 58 years ago, on Fri, Apr 26, 1968

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.