1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. SGLA36A10600

NSN SGLA36A10600

Circuit Breaker

A definite continuous length of cable,special purpose,electrical, having one or more ends processed or terminated in fittings which provide for connectionn to other items. For items which the rated working is 300 volts or more, see: cable assembly,power,electrical. Excludes items having branches or forks. Excludes: lead,test and cable and conduit assembly,electrical.

60.0 all locations frequency in hertz, series trip all locations internal trip release configuration, trip free main contact tripping mechanism type, trip-reset actuator function, overcurrent all locations circuit protection type.

NSN 5925-01-392-0881 Datasheet

(NSN) National Stock Number
5925-01-392-0881
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-392-0881
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Thu, Jun 23, 1994
Schedule B Code
8536200040
Actuator Function
trip-reset
Circuit Protection Type
overcurrent all locations
Frequency In Hertz
60.0 all locations
Internal Trip Release Configuration
series trip all locations
Main Contact Tripping Mechanism Type
trip free
Maximum Continuous Load Current Rating Per Pole
600.0 amperes ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
25000.0 ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Pole Quantity
3
Reset Method
manual
Trip Release Characteristic
instantaneous all locations
Trip Release Method
magnetic all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

60969
General Electric Co Electrical Distribution and Control
U.s./canadian manufacturers
86CP7
Abb Inc Div Electrification
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-392-0881?

    The FSCG of the NSN 5925-01-392-0881 is 5925

  2. Does the NSN 5925-01-392-0881 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-392-0881 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-392-0881 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-392-0881 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-392-0881 was assigned to the Federal Catalog?

    It was assigned 32 years ago, on Thu, Jun 23, 1994

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 1 day ago
View History